Lenovo 7Z59 Manual page 27

Hide thumbs Also See for 7Z59:
Table of Contents

Advertisement

• FQXSPBR4001I: Running the backup Management Controller [arg1] main application.
This message is for the use case where a Management Controller has resorted to running the backup
main application.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: System - other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0030
User Action:
Complete the following steps until the problem is solved:
1. Update the BMC firmware.
2. NOTE: Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
• FQXSPBR4002I: Management Controller [arg1] Reset was caused by restoring default values.
This message is for the use case where a Management Controller has been reset due to a user restoring
the configuration to default values.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0032
User Action:
Information only; no action is required.
• FQXSPBR4003I: Platform Watchdog Timer expired for [arg1].
This message is for the use case when an implementation has detected a Platform Watchdog Timer
Expired
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - OS Timeout
SNMP Trap ID: 21
CIM Prefix: IMM CIM ID: 0039
User Action:
Complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the BMC Ethernet-over-USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog timer.
.
Chapter 2
XClarity Controller events
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem sr860 v27z60

Table of Contents