3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0005I: An intra-board UPI has been disabled on the link between processor [arg1] port
[arg2] and processor [arg3]port [arg4] because of UPI topology downgrade.
Severity: Info
User Action:
Complete the following steps:
1. This event should be followed by a recent FQXSFIO0005M / FQXSFIO0006M event denoting some
UPI links failure which caused UPI topology downgrade.
2. Solve the event FQXSFIO0005M / FQXSFIO0006M at first, then this event should be solved
automatically.
3. If no recent or after fixing FQXSFIO0005M / FQXSFIO0006M event, this event still persists, collect
Service Data logs and contact Lenovo Support.
• FQXSFIO0005M: An intra-board UPI failure has been detected on the link between processor [arg1]
port [arg2] and processor [arg3] port [arg4].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this
error.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0006I: An inter-board UPI has been disabled on the link between processor [arg1] port
[arg2] and processor [arg3]port [arg4] because of UPI topology downgrade.
Severity: Info
User Action:
Complete the following steps:
1. This event should be followed by a recent FQXSFIO0005M / FQXSFIO0006M event denoting some
UPI links failure which caused UPI topology downgrade.
2. Solve the event FQXSFIO0005M / FQXSFIO0006M at first, then this event should be solved
automatically.
3. If no recent or after fixing FQXSFIO0005M / FQXSFIO0006M event, this event still persists, collect
Service Data logs and contact Lenovo Support.
• FQXSFIO0006M: An inter-board UPI failure has been detected on the link between processor [arg1]
port [arg2] and processor [arg3] port [arg4].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this
error.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0007M: An error has been detected by the IIO on Bus [arg1]. The value of Global Fatal
Error Status register is [arg2]. The value of Global Non-Fatal Error Status register is [arg3]. Please
check error logs for additional downstream device error data.
144