Lenovo 7Z59 Manual page 99

Hide thumbs Also See for 7Z59:
Table of Contents

Advertisement

• FQXSPPW0063M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps:
1. Perform virtual system reseat or A/C power cycle.
2. If the error still present, remove A/C power and any recently installed components.
3. If the server successfully powers on, complete the following steps:
a. Check the server proven website (http://www.lenovo.com/us/en/serverproven/index.shtml) to
make sure that recently installed components are compatible with the server.
b. Inspect the previously installed components for physical damage and resolve it.
c. If the system does not successfully power on or if this is not the first occurrence of this problem,
go to step 4.
4. If the system has stand-by power collect Service Data logs.
5. Contact Lenovo Support.
• FQXSPPW0101J: Redundancy Degraded for [RedundancySetElementName] has asserted.
This message is for the use case when Redundancy Degraded has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0804
User Action:
Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system.
• FQXSPPW0104J: Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted.
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or
Fully Redundant to Non-redundant:Sufficient.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0806
User Action:
.
Chapter 2
XClarity Controller events
95

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem sr860 v27z60

Table of Contents