2. RESEAT the DIMM that failed POST memory test and the DIMMs on adjacent slots if populated. Boot
to F1 setup and enable the DIMM. Reboot the system.
3. Swap the DIMM from failure location to another known good location to see if the failure follow the
DIMM or DIMM slot.
4. If this problem was encountered during an XCC / UEFI update process:
a. Power cycle the system by removing power for a few seconds.
b. Clear CMOS settings by removing battery for a few seconds.
5. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0009I: Invalid memory configuration for Mirror Mode has been recovered. [arg1]
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0009K: Invalid memory configuration for Mirror Mode. Please correct memory
configuration. [arg1]
Severity: Error
User Action:
Complete the following steps:
1. Ensure that all the DIMMs are enabled and functional by booting to F1 Setup or in XCC web .If any
DIMMs are non-functional adddress that first.
2. Make sure that the DIMM connectors are correctly populated for mirroring mode, according to the
service information for this product.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0010I: Invalid memory configuration for Sparing Mode has been recovered. [arg1]
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0010K: Invalid memory configuration for Sparing Mode. Please correct memory
configuration. [arg1]
Severity: Error
User Action:
Complete the following steps:
1. Ensure that all the DIMMs are enabled and functional by booting to F1 Setup or in XCC web .If any
DIMMs are non-functional adddress that first.
2. Make sure that the DIMM connectors are correctly populated for sparing mode, according to the
service information for this product.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0011I: Memory population change detected. [arg1]
Severity: Info
User Action:
Complete the following steps:
.