To learn more...

To select different Performance modes
converti7
This operation Changes Air Conditioner Performance in COOL Mode only.
• Step 1 : "HC" is display on Unit and Remote. Unit will operate in High Capacity Mode.
• Step 2 : "FC" is display on Unit and Remote. Unit Input Power will be upto 100%.
• Step 3 : "90" is display on Unit and Remote. Unit Input Power will be upto 90%.
• Step 4 : "80" is display on Unit and Remote. Unit Input Power will be upto 80%.
• Step 5 : "
• Step 6 : "55" is display on Unit and Remote. Unit Input Power will be upto 55%.
• Step 7 : "40" is display on Unit and Remote. Unit Input Power will be upto 40%.
• Press "
" button again to exit from this feature.
converti7
• Set temperature will display about 5 sec. if press fan speed button or change temperature.
• User can select Fan speed as per need.
• Capacity may decrease when "
• Capacity measurement is done Under Standard Lab condition and may vary based on Ambient
Temperature and Room Size.
• JETSTREAM, ECONAVI, SLEEP will not work in this mode and vice versa.
• "AI" mode is Applicable for Models having Wi-Fi Feature and it will be Accessible through MirAIe APP only.
* ECONAVI
Human activity sensor operation
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.
Mode
COOL
ECONAVI
Precise control of temperature during low activity to maximise energy saving.
Mode
COOL
The human activity sensor will also scan for area of heat source and movement in a room.
Detection area
120°
7m
• The human activity sensor may:
- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidifier from the sensor's detection
area. They may cause sensor malfunction.
12
Note:
* Not applicable for "WU", "XU", "PU" & "AU" series.
" is display on Unit and Remote. Unit Input Power will be upto 70%.
" mode is Selected.
converti7
The unit will start to initialise
(for approximately 1 minute)
Human
Low activity
Set
temperature
Human
Low activity
Set
temperature
• Based on area activeness horizontal airflow direction will adjust either fix
at predetermined position or swing left/right periodically.
This will be applicable only when Unit Horizontal Airflow is Set in Auto Swing
position.
• The human activity sensor performance is influenced by indoor unit
location, movement speed, temperature range, etc.
The human activity sensor
will start to detect.
Normal activity
+1°C
ECONAVI take advantage of the human nature that
human being takes time to feel the temperature rise
during low activity level; the unit adjusts temperature to
maximise energy saving without sacrificing the comfort.
High activity
Absent
+2°C

Hide quick links: