Operation mode
AUTO : During operation mode selection the POWER indicator blinks.
• Unit selects the operation mode according to the room temperature.
• Once AUTO mode is selected, the unit will operate at the standard setting temperature.
Room temperature
23 °C / 73 °F & above
Below 23 °C / 73 °F
• Press
for "HI" to +2 °C / +4 °F or
COOL : Provides efficient comfort cooling to suit your needs.
DRY
: Operates at low fan speed for a gentle cooling operation.
Energy saving temperature setting
You may save energy when operating the unit within the recommended temperature range.
COOL : 26 °C ~ 28 °C / 79 °F ~ 82 °F.
Air flow direction
In COOL/DRY mode:
The horizontal flap is fixed at middle position setting.
Once the temperature is achieved, the horizontal flap swings up/down automatically.
In COOL/DRY mode:
The horizontal flap swings up/down automatically.
Auto restart control
When power is resumed after a power failure, the operation will restart automatically with the
last operation mode and airflow direction.
• This control is not applicable when TIMER is set.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
COOL
DBT : Dry bulb temperature, WBT : Wet bulb temperature
30
Operation mode
for "LO" to -2 °C / -4 °F to the standard setting temperature.
DBT
Max.
32 (89.6)
Min.
16 (60.8)
COOL
DRY
Indoor
WBT
23 (73.4)
11 (51.8)
Standard setting temperature
25 °C / 77 °F
22 °C / 72 °F
Outdoor
DBT
55 (131)
31 (87.8)
16 (60.8)
11 (51.8)
WBT