12.5 Outdoor Unit

If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
There should not be any animal or plant which could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
Do not place any obstacles which may cause a short circuit of the discharged air.
If piping length is over the [piping length for additional gas], additional refrigerant should be added as shown in
the table.
Table A
Piping size
Capacity
Model
W (HP)
Gas
TZ20***
3/4HP
TZ25***,
9.52 mm
1.0HP
RZ25***
"
(3/8
)
TZ35***,
1.5HP
RZ35***
TZ42***
1.75HP
12.7 mm
TZ50***,
2.0HP
"
RZ50***
(1/2
)
TZ60***
2.25HP
15.88 mm
TZ71***
2.5HP
"
(5/8
)
(*) Systems with total refrigerant charge, m
Example: For TZ20***
If the unit is installed at 10 m distance, the quantity of additional refrigerant should be 25 g .... (10-7.5) m x 10 g/m =
25 g.
A
= (m
/ (2.5 × (LFL)
min
c
= Required minimum room area, in m
A
min
m
= Refrigerant charge in appliance, in kg
c
LFL
= Lower flammability limit (0.307 kg/m
h
= Installation height of the appliance (1.8 m for wall mounted)
0
= Safety factor with a value of 0.75
SF
** The required minimum room area, A
A
= m
min
c
The higher value shall be taken when determining the room area.
12.5.1
Outdoor Unit Installation Diagram
It is advisable to avoid more
than 2 blockage directions.
For better ventilation &
multiple-outdoor installation,
please consult authorized
dealer/specialist.
This illustration is for
explanation purposes only.
Std.
Length (m)
Elevation (m)
Liquid
6.35 mm
5
"
(1/4
)
, lower than 1.84 kg are not subjected to any room area requirements.
c
(5/4)
2
× h
))
0
2
3
)
, shall also be governed by the safety factor margin formula below :
min
/ (SF × LFL × h
)
0
Max
Min. Piping
Max. Piping
Length (m)
Length (m)
15
3
15
15
3
15
15
3
15
15
3
15
15
3
20
15
3
30
20
3
30
** not less than safety factor margin
78
Additional
Piping Length
Refrigerant
for add. gas
Refrigerant
(g/m)
(m)
Charge (kg)
10
7.5
10
7.5
10
7.5
10
7.5
15
10
15
10
25
10
Connection cable ( )
1/4" Liquid side piping ( )
Gas side piping ( )
Additional drain
hose ( )
Installation parts you
should purchase ( )
Max.
Indoor
2
A
(m
)
min
0.60
Not applicable (*)
0.69
Not applicable (*)
0.75
Not applicable (*)
0.87
Not applicable (*)
1.22
Not applicable (*)
1.52
Not applicable (*)
1.85
4.46