12.2 Indoor Unit

12.2.1
How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent it from vibration.
TZ20***, TZ25***, TZ35***,
TZ42***, TZ50***
RZ25***, RZ35***, RZ50***
The center of installation plate should be at more than 1 at right and left of the wall.
The distance from installation plate edge to ceiling should more than 2.
From installation plate center to unit's left side is 3.
From installation plate center to unit's right side is 4.
B : For left side piping, piping connection for liquid should be about 5 from this line.
: For left side piping, piping connection for gas should be about 6 from this line.
1
Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
o
a level gauge.
2
Drill the piping plate hole with ø70 mm hole-core drill.
Line according to the left and right side of the installation plate.
o
The meeting point of the extended line is the center of the hole.
Another method is by putting measuring tape at position as shown in the diagram above.
The hole center is obtained by measuring the distance namely 115 mm for left and right hole respectively.
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
o
side.
12.2.2
To Drill a Hole in the Wall and Install a Sleeve of Piping
1
Insert the piping sleeve to the hole.
2
Fix the bushing to the sleeve.
3
Cut the sleeve until it extrudes about 15 mm
from the wall.
When the wall is hollow, please be sure to use
the sleeve for tube assembly to prevent dangers
caused by mice biting the connection cable.
4
Finish by sealing the sleeve with putty or
caulking compound at the final stage.
Wall
168 mm
Measuring Tape
PIPE
HOLE
CENTER
115mm TO
HOLE CENTER
115 mm
Model
CAUTION
Ceiling
More than
1
More
2 screw
than
2
3
6
Installation
5
plate 1
For best strength of
INDOOR unit installation,
it is highly recommended
to locate " " at 5 position
as shown.
1
2
465 mm
70 mm ( * )
365 mm
Sleeve for tube
assembly
60
More than
1
Wall
Indoor unit
4
4
216 mm
PIPE HOLE
CENTER
115mm TO
HOLE CENTER
115 mm
Dimension
3
4
5
415 mm
60 mm
Dimension 2
(*) :-
If holder at the rear of chassis
(Refer column "12.2.3 Indoor
Unit Installation") need to be
used to prop up the unit, this
distance shall be 85 mm or
more.
Wall
Indoor
Outdoor
15 mm
ø70 mm
Putty or caulking compound
through hole
6
120 mm
Approx. 5 - 7 mm
Bushing for
tube assembly