Page 386 of 396

Introduction

NT5K40AA, NT5K41AA, NT5K86AA

553-3001-201
Standard 1.00
Non-standard cables
This section provides information required to build systems cables of
non-standard lengths for ISDN PRI applications.
These cables are used to transport the 2Mb digital signal from the faceplate
connector on the PRI card to the Line Terminating Equipment interface.
Standard lengths:
— NT5K40AA - 4 m (13 ft.)
— NT5K41AA - 8 m (26 ft.)
— NT5K86AA - 12m (39 ft.)
Construction - 75 ohm dual co-axial type with solid inner conductor and
braided shield.
J1 Connector - 15-pin, male, subminiature D with jack-screws
J2 Connector - 75 ohm BNC crimp plug
J3 Connector - 75 ohm BNC crimp plug
Table 107
NT5K40AA, NT5K41AA, NT5K86AA wire list
From
(pack end)
J1-1
J1-9
J1-3
J1-11
J1-9
October 2003
To
(I/O end)
J2 Inner Conductor
J2 Shield
J3 Inner Conductor
J3 Shield
J3 Shield
Signal
XTIP (transmit)
XRING (transmit)
RTIP (receive)
RRING (receive)
FRAME GROUND