Becker P5-16-C01 Assembly And Operating Instructions Manual

Roller shutter drive with integrated radio receiver

Advertisement

Quick Links

P5-16...R40-17
Model: C01
Assembly and Operating Instructions
en
Roller shutter drive with integrated radio receiver
Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.
2010 301 106 0b     13/09/2022    
Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P5-16-C01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Becker P5-16-C01

  • Page 1 Roller shutter drive with integrated radio receiver Important information for: • Fitters / • Electricians / • Users Please forward accordingly! These instructions must be kept safe for future reference. 2010 301 106 0b     13/09/2022     Becker-Antriebe GmbH Friedrich-Ebert-Straße 2-4 35764 Sinn/Germany www.becker-antriebe.com...
  • Page 2: Table Of Contents

    Table of contents General .................................... 3 Warranty .....................................  4 Safety instructions ................................ 4 Instructions for the user.............................. 4 Instructions for installation and commissioning........................ 4 Intended use .................................. 6 Assembling and disassembling the plug-in connecting cable.................... 6 Assembly ....................................  7 First operation ...................................  10 Programming the master transmitter ..........................
  • Page 3: General

    General These tubular drives are high-quality products with the following features: • Optimised for roller shutter operation • Individual, group and central radio control • No need to run wires to a switch or relay control device • Any combination of drive and transmitter possible •...
  • Page 4: Warranty

    Warranty Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in serious injuries, e.g., crushing of limbs. Therefore, structural modifications may only be carried out with our prior approval and strictly in accordance with our instructions, particularly the information contained in these Assembly and Operating Instructions. Any further processing of the products which does not comply with their intended use is not permitted.
  • Page 5 • Hazardous moving parts of the drive must be installed at a height of over 2.5 m above floor level or any other surface from which the drive can be accessed. • To ensure safe operation of the system after commissioning, the limit positions must be correctly set/ programmed in.
  • Page 6: Intended Use

    Intended use The type of tubular drive described in these instructions is intended solely for the operation of roller shutters. This type of tubular drive supports not only curtain attachment by means of springs but also rigid shaft connectors, such as mech- anical anti-lifting devices manufactured by Zurfluh-Feller, Simu, GAH Alberts and Deprat.
  • Page 7: Assembly

    Disassembling the plug-in connecting cable for tubular drives Insert a suitable flathead screwdriver between the locating lug Ø35 and the snap-in pin, so that the snap-in pin releases the locat- ing lug from the plug. Now you can pull out the connecting cable along with the flat- head screwdriver.
  • Page 8 Assembling and disassembling the mounting pin Ø45 When pushed in, the mounting pin (2) locks automatically. To undo the mounting pin (2), push the tab washer (1) upwards and pull out the mounting pin (2). If you wish to use the "obstacle detection" function, you must use the "drive adapter for obstacle detection".
  • Page 9 Size of drive Drive adapter Torque Fastening screws [mm] max. [Nm] (4 units) dia. 35-dia. 45 Up to 50 Self-tapping screw dia. 4.8 x 9.5 mm We also recommend screwing the idler to the barrel. Attention Do not hammer the tubular drive into the tube or drop it into the barrel! The curtain can only be secured using springs or rigid shaft connectors.
  • Page 10: First Operation

    First operation Explanation of symbols UP button STOP button DOWN button Programming button (on the transmitter) Receiver confirms once or multiple times by "clicking" or "shifting" 1 = direction switch 2 = radio switch Attention The tubular drives are designed for short-time operation. An inbuilt thermal protection switch prevents overheating of the tubular drive.
  • Page 11: Programming The Master Transmitter

    Programming the master transmitter Press the programming button for 3 seconds when it is ready to programme. ▻ The tubular drive acknowledges. ► The programming process is now complete. If a transmitter is already programmed on the receiver, press the programming button for 10 seconds.
  • Page 12: Intelligent Installation Management

    Intelligent installation management Completion of installation following automatic setting of limit positions The drive saves the limit position permanently once the upper limit position is reached 3 times in succession. Installation is then complete. If the limit position is set above a point, this is stored permanently. Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that direction of movement.
  • Page 13: Changing The Set Limit Positions

    Upper stop to lower point Open to the permanent upper stop. ▻ The tubular drive switches off automatically. Then close to the desired lower limit position. Press the programming button and, within 3 seconds, also press the button and hold the two buttons down. ▻...
  • Page 14: Deleting The Limit Positions

    2) Extending the range of travel (the desired limit position is located outside the current range of travel) Attention When both or individual limit positions are deleted, all the other set functions (intermediate position I, intermediate position II, upper anti-freeze mechanism, obstacle detection, run times, fly screen protection function) are deleted as well.
  • Page 15: Intermediate Positions I + Ii

    Intermediate positions I + II The intermediate positions I + II are freely selectable positions for the shading solution between the two limit positions. Each travel button can be assigned one intermediate posi- tion. Both limit positions must be set before an intermediate position is set. Setting/modifying the desired intermediate position Open/close the shading solution to the desired intermediate position.
  • Page 16: Deleting Transmitters

    Deleting transmitters Deleting individual transmitters The programmed master transmitter cannot be deleted. It can only be overwritten (see Programming the master transmitter [} 11]). Press the programming button on the master transmitter for 3 seconds. ▻ The tubular drive acknowledges. Now press the programming button of the transmitter to be deleted for 3 seconds. ▻...
  • Page 17: Local Operation With A Single Button

    Now press the programming button of the new master transmitter for 10 seconds. ▻ The tubular drive acknowledges. ► The new master transmitter has now been programmed and the old master trans- mitter overwritten. Readying the tubular drive for programming with the radio switch Switch the radio switch to the inside position.
  • Page 18: Upper Anti-Freeze Mechanism

    Upper anti-freeze mechanism The upper anti-freeze mechanism helps to prevent the roller shutter from freezing in the upper limit position, as the roller shutter stops just before the upper stop. The distance from the upper stop is automatically cyclically checked and, if necessary, correc- ted.
  • Page 19: Fly Screen Protection Function

    ► The tubular drive confirms. Programming the run times This function is only available with MemoControl transmitters from the Becker Centronic range of control units. This tubular drive can save one switching time for one UP and one DOWN cycle.
  • Page 20: Technical Data Dia. 35

    Technical data dia. 35 Tubular drive P5-16 P9-16 Model Type C PROF+ V1 Rated torque [Nm] Output speed [rpm] Limit switch range 64 revolutions Supply voltage 230 V AC / 50 Hz Connected load [W] Rated current consumption [A] 0.36 0.47 Mode S2 4 min...
  • Page 21: What To Do If

    What to do if...? Problem Remedy Tubular drive does not move. Program new transmitter. Bring transmitter within range of the tubular drive. Press drive or stop button on transmitter at least five times in the immediate vicinity of the tubular drive. Insert battery/batteries correctly in the transmitter or insert new battery/batteries.
  • Page 22: Sample Wiring Diagram

    Sample wiring diagram 22 - en...
  • Page 23: Declaration Of Conformity

    Declaration of conformity For UK-Markets: The Declaration of Conformity can be provided upon request from Becker Motors Ltd., or can be downloaded on www.beckermo- tors.co.uk. 23 - en...

This manual is also suitable for:

R40-17-c01

Table of Contents