Download Print this page

Hans Grohe Aqittura M91 210 1jet sBox 76800 Series Instructions For Use/Assembly Instructions page 4

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• The flush water initially exhibits a milky cloudiness. This is caused by the
dispersed air and will clear after a short while.
• Check the correct position of the filter cartridge in the filter bowl by means of the
markings on wall holder and filter cartridge.Pay attention to the position of the
label when inserting the cartridge.It should face forward so that all the required
information is visible.
• Please enter the date of installation and the time of replacement into the
corresponding fields on the filter cartridge label.
Technical Data
Withdrawal amount of filtered water:
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
see label on the filter cartridge
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
No drinking water
Adjustment (see page 25)
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
Maintenance (see page 29)
The check valves must be checked regularly according to EN 806-5 in accordance
with national or regional regulations (at least once a year).
Fault
Insufficient water
Mixer stiff
Mixer dripping
Water escaping at the threaded base
Hot water temperature too low
4
English
1,3 l/min
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
Replace the filter after 1/2 year of non-use and/or after 4 weeks without water
being released. Wear sterile disposable gloves when replacing the filter cartridges.
To determine the carbonate hardness in local tap water, use an appropriate test kit.
If a test kit is not available, please ask your water utility.
Hansgrohe recommends not to use as drinking water the first half liter of water
drawn in the morning or after a prolonged period of non-use.
Cause
- Aerator calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
- connection hoses not completely screwed into basic
body
- O-ring at the connection hose defective.
- Hot water limiter incorrectly set
Assembly (see page 21)
Dimensions (see page 27)
Flow diagram (see page 27)
Spare parts (see page 31)
XXX = Colors
000 = Chrome Plated
670 = Matt Black
800 = Stainless Steel Optic
+
Special accessories (order as an extra)
(see page 30)
• Filter with activated carbon #76814000
• Filter with activated carbon and ion exchanger #76815000
• Filter with activated carbon and ion exchanger Pro #76827000
• Filter with activated carbon and mineralisation (Harmony) #76828000
• Filter with activated carbon and mineralisation (Life) #76829000
• Filter with activated carbon and mineralisation (Sport) #76830000
• Flow meter #76818000
extension #43333000 (see page 26)
Cleaning (see page 28)
Filter replacement (see page 30)
Bypass positon #76815000, #76827000 (see page 29)
Operation (see page 26)
Test certificate (see page 32)
Remedy
- Clean aerator, replace as necessary
- Exchange cartridge
- Exchange cartridge
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter

Advertisement

loading

This manual is also suitable for:

Aqittura m91 210 1jet sbox 76826 series