Advanced Setup Menu - Sharp AN-LS1 Operation Manual

Ethernet to rs-232c network converter
Hide thumbs Also See for AN-LS1:
Table of Contents

Advertisement

ADVANCED SETUP MENU

******************** ADVANCED SETUP MENU ***********************
[1]Auto Logout Time [2]COM Redirect Port [3]Busy Reply
[4]Input Hold Time
[6]Accept IP Addr(1) [7]Accept IP Addr(2)
[9]Accept All IP Addr [0]Port for Search
[!]Restore Default Setting
[Q]Return to Main Menu
advanced>
[1] Auto Logout Time (Factory default setting : 5 minutes)
Setting of time until automatic disconnection of network connection.
[2] COM Redirect Port (Factory default setting : 10002)
Setting of TCP port No. capable of connecting using Sharp COM Redirection Software.
[3] Busy Reply (Factory default setting : ERR + <CR> code)
When separate devices are connected to the two control terminals (RS-232C (CONTROLLER)
and 10BASE-T), it is not possible to use one control terminal while data is being transmitted using
the other control terminal.
This setting is for operation of the control terminal that cannot be used.
(Page
[4] Input Hold Time (Factory default setting : 1000 milliseconds)
Changing value for Input Hold Time when a response is not returned from a projector within a set
time while separate devices are connected to the two control terminals (RS-232C (CONTROLLER)
and 10BASE-T).
[5] Network Ping Test
It is possible to confirm that a network connection between AN-LS1 and a computer etc. is working
normally.
[6] Accept IP Addr(1)
[7] Accept IP Addr(2)
[8] Accept IP Addr(3)
[9] Accept All IP Addr (Factory default setting : Accept All)
For improved security, it is possible to set up to three IP addresses allowing connection to AN-
LS1. Set IP addresses can be cancelled using [9] Accept All IP Addr.
[0] Port for Search (Factory default setting : 5006)
Setting for port number used when Sharp COM Redirection Software searches for AN-LS1.
24)
[!] Restore Default Setting
Restores all setting values that can be set using the menu to the default state.
(Page
[Q] Return to Main Menu
Return to the main SETUP MENU.
[5]Network Ping Test
22)
(Page
22)
(Page
23)
24)
[8]Accept IP Addr(3)
(Page
24)
14
(Page
21)
(Page
(Page
23)
(Page
21)

Advertisement