Accessing the Dewaterer belt & pulleys
1. Remove the rear panel to access the underside of the dewaterering unit
2. Remove the dewatering service panel by unscrewing the two bolts and the panel will drop down, this will
give access to both the pulley belts and the pulleys
Accessing the Dewaterer top flange, seals and bearings
1. Remove the 3 off alum key to remove the top flange
and expose the top of the auger assembly.
2. Within the flange removed there is two seals
EP090117 (45x58x7) and EP090116 Lip Seal 45x65x8.
3.
To remove the top housing assembly unscrew the 4 off
Alum screws securing the top housing to the stainless steel
body.
4. This will give access to the top bearing EP090123 and
Lip Seal EP090116 (45x65x8) shown below.
Ecofast Environmental UK Ltd
25