Macerator maintenance
Remove rear panel, disconnect macerator wires and pipes. Pull the macerator out towards machine's back and
once macerator is clear of the WasteStation.
1. Loosen all 6 bolts to release the top cone
2. Lift the top cone
3. Remove the grinding ring and gasket
4. Using the EC000750 rotor release tool, extract the rotor from the motor top housing.
Dewaterer removal
1. Remove front, side, rear panels.
2. Disconnect and remove water supply assemblies,
then side crossbar.
3. Disconnect the green/yellow pipe, remove the
flange and manifold
4. Disconnect all pipes from the dewaterer.
5. Unscrew and pull out the dewaterer
1
Ecofast Environmental UK Ltd
2
3
4
EC000750 - tool 5
24