Trouble Shooting & Fault Finding - EcoFast D600 Product Manual

Food waste dehydra mini dewaterer
Table of Contents

Advertisement

Warranty Details
This product comes with a 2-year parts and labour warranty in the UK and 2 years parts only in exported
regions. The warranty period is based on fair industry usage, regular service reviews in line with Ecofast
recommendations or a maximum run time of 2,200 hours over the warranty period.
The product's onboard PLC (computer) will log running times which can be monitored remotely by
Ecofast UK as an optional extra to provide a surveillance, problems solving and preventative
maintenance service.
Spare Parts come with a limited 3-month parts only warranty from the point of purchase.
Trouble shooting & fault finding
Error fault codes – in the event of activation these error messages are display
on the operator display.
Error Message
Corrective action
Motor overload
Isolate power to the machine, check for & remove any blockage, turn
power back on. Wait for alarm to reset. Contact service dept if
message continues.
No Water
Check water supply and restart – alarm will reset if water present
Phase error
Contact electrician for corrective action
Bin is full
Empty bin & restart machine
Emergency
Check baffle and bin are correctly fitted
Should the above corrective actions not overcome the faults, try the additional actions;
MACHINE
Situation
Object jammed in the
macerator
Bin is full but the machine
doesn't stop;
or display shows BIN FULL
but the bin isn't full
Machine works but drops
nothing into the bin
Macerator hopper is
flooding
Action
Try unjamming the rotor by special tool EC000755. Remove the
macerator and disassemble it to remove the jammed object.
Replace the macerator
Stop the machine, remove I/O panel and manually test the level
sensor (page 10). Check whether led colour on sensor swaps
together with display message. Check sensor's switch
distances by hand. Replace the sensor.
Press emergency button unplug power cord and remove
possible clogging along the material's path. Run one or more
cleaning cycles. Remove and inspect the dewaterer. Replace
the dewaterer.
Stop the machine normally. Remove I/O panel and check for the
pump to work. Check pump's wiring. Remove pump's cap and
let the material out. Unjam and replace pump's impeller
Ecofast Environmental UK Ltd
ISOLATE
13

Advertisement

Table of Contents
loading

Related Products for EcoFast D600

Table of Contents