Maintenance
– Any maintenance should be undertaken by an approved Ecofast
service agent.
When the display shows MAINTENANCE NEEDED, that must be carried out as soon as possible.
Maintenance times are reliant on the correct use of the machine, type of food waste, available water. Thus it's
operator's duty to follow the timeframes of regular maintenance times based on these parameters. This paragraph
refers to a correct use of the machine which follows the instructions in this manual.
When maintenance is over, ensure the castors are lowered and locked into the correct positions detailed in the
installation section of this manual.
Pump service
Remove the pump unscrewing the 2 nuts (see red
arrow), replace the impeller (1) and seals (2), inspect the
O-rings (3) and replace if needed. If there is any damage
to the pump assembly replace
the
whole assembly.
2
3
1
3
Clean filter(s)
PLEASE NOTE: in new buildings it is possible the
water system carries much debris at start up, it may
be required to check the filters regularly.
Unscrew the caps at the bottom of the Y-type
strainer & rinse out any debris. Replace the filter
and ensure the caps are secured firmly in place.
General Inspection
Check warning labels and replace them if worn.
Macerator: check wear status of grinding rotor and ring, and replace them if needed. Replace seals in
case of leakages. Ensure there is no water present in the leak pipe located coming out of the macerator
casting.
Dewaterer: check to ensure there is no liquid in the leak detection pipe on the dewaterer base casting.
Check for odd noise while rotating the belt and pulleys. If needed, replace the cylinder.