Connection Overview - Victron energy MultiPlus-II 230V Manual

Table of Contents

Advertisement

Appendix A. Connection overview
MultiPlus-II 3000VA & 5000VA
A
Load connection. AC out1. Left to right: N (neutral), PE (earth/ground), L (phase)
B
Load connection. AC out2. Left to right: N (neutral), PE (earth/ground), L (phase)
C
AC input: Left to right: N (neutral), PE (earth/ground), L (phase)
D
Alarm contact: (left to right) NO, NC, COM.
E
Push button A – To perform a startup without assistants.
F
Primary ground connection M6 (PE).
G
M8 battery positive connection.
H
M8 battery minus connection.
I
switch: 1=On, 0=Off, ||=charger only
J
Connector for remote switch: Short to switch "on".
K
2x RJ45 VE-BUS connector for remote control and/or parallel / three-phase operation
L
External current sensor
To connect the current sensor; remove the wire bridge between the INT and COM terminals, connect the red sensor
wire to the EXT terminal and connect the white sensor wire to the COM terminal.
Page 31
MultiPlus-II 230V

Connection overview