APPENDIX A: Connection overview

EN:
A AC input (generator input) AC-in-1.
B 2x RJ45 connector for remote panel and/or parallel and 3-phase operation.
C AC output AC-out-1.
D AC output AC-out-2.
E Terminals for: (left to right)
Temperature sensor
Aux input 1
Aux input 2
GND-relay
Starter battery plus + (starter battery minus must be connected to service battery minus)
Programmable relay contacts K1
Programmable relay contacts K2
Voltage sense
F
Double M8 battery minus connection.
G Double M8 battery positive connection.
H Connector for remote switch:
Short left and middle terminal to switch "on".
Short right and middle terminal to switch to "charger only".
I
Alarm contact: (left to right) NC, NO, COM.
J
AC input (shore/grid supply) AC-in-2. Left to right: L (phase), N (neutral), GROUND (earth).
K Pushbuttons for set-up mode
L
Primary ground connection (PE).
M DIP switches for set-up mode.
N Slide switches, factory setting SW1= right position, SW2 = right position.
SW1: No application. To be used for future features.
SW2: INT(R) = internal GND relay selected, EXT(L) = external GND relay selected (to connect ext GND relay: see E).
Left to right: GROUND (earth), L (phase), N (neutral).
Left to right: L (phase), N (neutral), GROUND (earth).
Left to right: L (phase), N (neutral).