5.4
Working position
The burner is designed to operate only in the po-
sition 1. (Fig. 5).
WARNING
1
5.5
Securing the burner to the boiler
Provide an adequate lifting system of the burner.
It is necessary that the insulating gasket 9)(Fig. 1) is placed
between the boiler door and the burner flange.
The insulating gasket has six holes, which, if necessary, can
be modified as shown in Fig. 6.
Put on the flange 1)(Fig. 7) the screw 2) and two nuts 3).
Verify that the installed burner is lightly leaned towards the
button (Fig. 8).
D5242
2
1
20163551
Installation
2
Fig. 6
3
S7386
Fig. 7
10
Any other position could compromise the correct
operation of the appliance.
Installations 2, 3, 4 and 5 are forbidden for safety
DANGER
reasons.
3
4
D5218
GB
5
20185476
Fig. 5
Fig. 8