CLEI code is
switch#

Displaying the Hardware Inventory for a Switch

You can display information about the field replaceable units (FRUs), including product IDs, serial numbers,
and version IDs by using the show inventory command. The output for this command displays information
about modules that respond to command line interface commands. Modules such as supervisors, system
controllers, line cards, fans, fabric modules, and power supplies. But does not display information for modules
that do not respond to those commands, such as blank modules that cover empty slots to manage airflow.
switch# show inventory
NAME: "Chassis",
PID: N9K-C9504
NAME: "Slot 2",
PID: N9K-X9716D-GX
NAME: "Slot 3",
PID: N9K-X9736C-EX
NAME: "Slot 22",
PID: N9K-C9504-FM-G
NAME: "Slot 23",
PID: N9K-C9504-FM-G
NAME: "Slot 24",
PID: N9K-C9504-FM-E
NAME: "Slot 25",
PID: N9K-C9504-FM-G
NAME: "Slot 28",
PID: N9K-SUP-B
NAME: "Slot 30",
PID: N9K-SC-A
NAME: "Power Supply 3",
PID: N9K-PAC-3000W-B
NAME: "Power Supply 4",
PID: N9K-PAC-3000W-B
NAME: "Fan 2",
PID: N9K-C9504-FAN
NAME: "Fan 3",
PID: N9K-C9504-FAN
switch#

Displaying Fabric Utilization Information

You can display information about hardware capacity in the module by using the show hardware capacity
command. This information includes total fabric bandwidth, utilization ingress and egress, module type,
DESCR: "Nexus9000 C9504 (4 Slot) Chassis"
,
VID: V01 ,
DESCR: "16x400G Ethernet Module"
,
VID: V01 ,
DESCR: "36x100G Ethernet Module"
,
VID: V01 ,
DESCR: "4-slot Fabric Module"
,
VID: V00 ,
DESCR: "4-slot Fabric Module"
,
VID: V00 ,
DESCR: "4-slot Fabric Module"
,
VID: V02 ,
DESCR: "4-slot Fabric Module"
,
VID: V00 ,
DESCR: "Supervisor Module"
,
VID: V02 ,
DESCR: "System Controller"
,
VID: V01 ,
DESCR: "Nexus9000 C9504 (4 Slot) Chassis Power Supply"
,
VID: V03 ,
DESCR: "Nexus9000 C9504 (4 Slot) Chassis Power Supply"
,
VID: V03 ,
DESCR: "Nexus9000 C9504 (4 Slot) Chassis Fan Module"
,
VID: V01 ,
DESCR: "Nexus9000 C9504 (4 Slot) Chassis Fan Module"
,
VID: V01 ,
Cisco Nexus 9504 NX-OS Mode Switch Hardware Installation Guide

Displaying the Hardware Inventory for a Switch

SN: FOX2150PHQU
SN: FOC24322R8V
SN: FOC23465C14
SN: FOC24432RQ9
SN: FOC24432RQ5
SN: FOC24294DUB
SN: FOC24432RRW
SN: FOC211761M5
SN: FOC22040SGR
SN: DTM220700SY
SN: DTM220700T3
SN: FOX2149P6Y3
SN: FOX2414P24S
49