Advertisement

Delivery measures

4.2 Battery

WARNING!
Measures after contact with acid
External:
Rinse with plenty of water.
Internal:
Drink plenty of water or milk. Seek
medical attention as quickly as possible.
Eyes:
Rinse with plenty of water. Seek medical
attention as quickly as possible.
The battery generates explosive gases.
Sparks, flames and cigarettes must not occur
Starting the engine with a weak battery
If the battery is too weak to start the engine, it should
be recharged. Charge the battery with max 3 Amps
for 4 hours.
When the battery is fully charged, connect the red
cable to the positive terminal (+terminal) of the
battery and the black cable to the negative terminal
(-terminal). Ensure that the red (+) cable is routed
behind the black (-) cable.
If jump leads are used for emergency starting, follow
the procedure below:
10 – English

4.3 Connecting the jump leads

IMPORTANT INFORMATION
Your rider is equipped with a 12-volt
system with negative ground. The other
vehicle must also have a 12-volt system
with negative ground. Do not use your
product battery to start other vehicles.
• Connect each end of the red cable to the
POSITIVE pole (+) on each battery, exercise care
not to short circuit any of the ends against the
chassis.
• Connect one end of the black cable to the
NEGATIVE pole (-) on the fully charged battery.
• Connect the other end of the black cable to a good
CHASSIS EARTH, away from the fuel tank and the
battery.
To remove cables, reverse order
• Remove BLACK cable first from chassis and then
from the fully charged battery.
• Finally the RED cable from both batteries.