Features; Technical Specifications; En50131-1 Installation Requirements; Ratings Compatibility - DSC TL280LE-LAT Instruction Manual

Hide thumbs Also See for TL280LE-LAT:
Table of Contents

Advertisement

128-bit AES encryption via cellular and Ethernet/Internet
l
- NIST validation cert number 2645 (for models TL2803G(R)E/3G2080(R)E/TL280(R)E
- NIST validation cert number 4475 (for models TL280LE(R)/LE2080(R))
Backup or primary cellular alarm communication.
l
Automatically converts to 2G (EDGE/GPRS) if HSPA(3G) service is not available (2G not supported on European models
l
only).
Automatically switches from LTE to HSPA(3G) service if LTE service is not available.
l
Ethernet LAN/WAN 10/100 BASE-T (TL2803G(R)E, TL280(R)E, TL280LE(R) only).
l
Fully redundant Ethernet/Internet and cellular dual-path alarm communication (TL2803G(R)E, TL280LE(R) only).
l
Full event reporting to the central station.
l
Individual Internet and/or cellular periodic test transmission.
l
Integrated call routing.
l
Visual Verification (Requires Sur-Gard System 5 Receiver)
l
Remote firmware upgrade capability of the communicator and panel firmware via Ethernet and/or cellular.
l
Panel remote uploading/downloading support via cellular and Ethernet/Internet.
l
PC-LINK connection.
l
Programmable labels.
l
SIA and Contact ID (CID) formats supported.
l
Signal strength and trouble display LEDs.
l
Supervision heartbeats sent via cellular and Ethernet/Internet.
l
Third-party integration over cellular/IP. The product supports third-party application via serial (R-models only), cellular
l
and Ethernet. Refer to third-party application documentation for more information.
NOTE: RS-232 connection is for supplementary use only and was not evaluated by UL/ULC.
The TL2803G(R)E/TL280LE(R) are also suitable to be used with a compatible control unit listed for dual line security trans-
mission when used in conjunction with a DACT or a Public Switched Data Network (PSDN) transmitter, where the PSDN
provides the line security and is the primary line. In this mode, alarm signals are to be sent simultaneously over both com-
munication methods.
For EN50131- 1 compliant installations, the following programming options shall be set as described. Supervision Heart-
beat (required for ATS4 and ATS5):
NOTE: The compatible receiver at ARC location shall have the supervision window programmed for 1800s (ATS4) or 180s
(ATS5) for the primary communications path, which can be Ethernet receiver 1 or cellular receiver 1, depending on
the product being installed.
[851][107]
Set to 0087h (135s Heartbeat) for Ethernet Receiver 1
l
[851][207]
Set to 0087h (135s Heartbeat) for Cellular Receiver 1
l
[851][100]
Options 1 and 2 shall be enabled if using Ethernet Receiver 1 as the primary path
l
[851][200]
Options 1 and 2 shall be enabled if using Cellular Receiver 1 as the primary path
l
Configuration of communication paths (all ATS classes)
[300][001]
select option 02 for auto routing (this will allow transmission of the events over all available communication
l
paths in the system)
[380]
enable option 5 (YES) for parallel transmission over all available communication paths (if redundant con-
l
figuration is desired)
[382]
enable option 5 (YES) to enable Alternate communicator
l
[384]
enable the desired back-up configuration (receiver 2 back-up for receiver 1 or receiver 3 back-up for receiver 1).
l

Technical Specifications

EN50131-1 Installation Requirements

Ratings Compatibility

Table 6: Communicator Ratings

Features

9