Field Wiring - Chamberlain LiftMaster CSW200101U Installation Manual

Commercial high-traffic ac swing gate operator
Table of Contents

Advertisement

To protect against fire and electrocution:
• DISCONNECT power BEFORE installing or servicing operator.

FIELD WIRING

Please see the wiring diagram included with your operator for more detailed wiring instructions.
BIPART
DELAY
4
2
OPEN
OPEN
LEFT
RIGHT
HANDING
CURRENT
MOTOR DRIVE
ANTENNA
ID RESET
SENSOR
PLUG-IN LOOP DETECTOR
Model LOOPDETLM
EXPANSION BOARD
SHADOW INTERUPT
EXIT
AUXILIARY
INTERRUPT
LOOP
SHADOW LOOP
EXIT LOOP
ADDITIONAL WIRING
CONTROL BOARD
6
8
RPM & LIMITS ALARM EXP.
24 VAC IN
BOARD
NOTE: These switches determine if the
corresponding photoelectric sensor or edge
sensor will function for the OPEN or CLOSE
POWER
+
EYE
1
ONLY
+
EYE/
2
EDGE
+
EYE/
3
EDGE
COM
+
SBC
+
OPN
+
CLS
+
STP
N.C.
COM
NOTE: These switches control how
the Auxiliary Relays will function.
AUXILIARY
RELAY 1
RELAY 2
For continued protection against fire:
• Replace ONLY with fuse of same type and rating.
+
3-BUTTON
+
+
CONTROL
N.C.
STATION
+
FIRE DEPARTMENT
EXIT LOOP
+
SHADOW LOOP
+
+
+
+
N.C.
COM
N.O.
ACCESSORY
+
POWER
24 Vac 500 mA
Maximum
PHOTOELECTRIC SENSORS
PHOTOELECTRIC SENSORS or
EDGE SENSORS
SINGLE BUTTON
CONTROL STATION
3-BUTTON
CONTROL STATION
35
OPEN and COM: Hard Open (line-of-sight)
CLOSE and COM: Hard Close (line-of-sight)
STOP and COM: Hard Stop (line-of-sight)
EXIT: Soft Open (used for exit probe,
telephone entry, external exit loop detector,
or any device that would command the
gate to open)
INTERRUPT LOOP or
PHOTOELECTRIC SENSORS for CLOSE cycle
EDGE SENSOR for CLOSE cycle
Shielded Twisted Pair Cable (Primary/Secondary
link to other gate operator) Ground the shield of the
cable to the chassis ground of each operator.
Solenoid Lock
(Optional)
OR
(Not Provided)
HEATER
JUNCTION BOX
Incoming Power
EDGE SENSOR or
PHOTOELECTRIC
SENSORS
for OPEN cycle
Maglock
(Optional)
(Not Provided)

Advertisement