Chamberlain MEGA SLIDE-X Owner's Manual

1/2 hp commercial duty slide gate operator

Advertisement

The Chamberlain Group, Inc.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
www.liftmaster.com
Model MSLXDCBB3
(MEGA SLIDE X)
1/2 HP COMMERCIAL DUTY SLIDE GATE OPERATOR
OWNER'S MANUAL
THIS UNIT IS A CLASS 1, 2, 3, OR 4 SLIDE GATE OPERATOR FOR USE IN SLIDE GATE APPLICATIONS

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain MEGA SLIDE-X

  • Page 1 The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com Model MSLXDCBB3 (MEGA SLIDE X) 1/2 HP COMMERCIAL DUTY SLIDE GATE OPERATOR OWNER’S MANUAL THIS UNIT IS A CLASS 1, 2, 3, OR 4 SLIDE GATE OPERATOR FOR USE IN SLIDE GATE APPLICATIONS...
  • Page 2: Table Of Contents

    T A B L E O F C O N T E N T S REPAIR PARTS INTRODUCTION Carton Inventory........3 ACCESSORIES Manual Release .
  • Page 3: Introduction

    I N T R O D U C T I O N CARTON INVENTORY Before beginning your installation check that all components were provided and received undamaged. Refer to list below for factory provided parts. Description Qty. Operator Accessory Shelf Owner’s Manual Gate Pull Tabs with Hardware (MS205 Pull Tabs, MS204 Chain Bolt)
  • Page 4: Ul325 Model Classifications

    UL325 ENTRAPMENT PROTECTION REQUIREMENTS SAFETY ACCESSORY SELECTION All UL325 compliant LiftMaster gate operators will accept external GATE OPERATOR ENTRAPMENT PROTECTION entrapment protection devices to protect people from motorized UL325 Slide Gate Operator Swing &...
  • Page 5: Safety Installation Information

    SAFETY INSTALLATION INFORMATION 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application. 2. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application.
  • Page 6: Recommended Site Layout Example

    RECOMMENDED SITE LAYOUT EXAMPLE Please use all safety devices that may apply to your installation to achieve the safest operation. (This is a view from above gate.) Safety Photo Beam (NOTE-2) Stop Photo Beam (NOTE-1) Stop Edge (NOTE-2 and 4) Stop Edge (NOTE-2 and 4) Gate Stops Here Stop Edge (NOTE-2)
  • Page 7: Safety Precautions For Roller Gates

    SAFETY PRECAUTIONS FOR OPEN ROLLER GATES Gate Edge on Fence Post Gate Edge on Rear for Open Direction Gate Edge on of Gate for Open WARNING WARNING WARNING Leading Edge of Gate for Direction Close Direction • Injuries occur when people get their hands or feet caught CAUTION between the top or bottom of the gate and the gate roller.
  • Page 8: Operator Overview

    OPERATOR OVERVIEW The LiftMaster model MEGA SLIDE X slide gate operator is unique in the industry. Setting the MEGA SLIDE X apart are many features that make it the front runner in its class. With standard features like: • Built in battery run - inherent 24 Vdc backup power with regulated 24 Vdc for accessories.
  • Page 9: Installation

    I N S T A L L A T I O N CONCRETE PAD CHAIN INSTALLATION The concrete pad for operator mounting should be approximately Before beginning to install the chain, be sure that the centerline of 24" x 24" x 24" in order to provide adequate weight and structure the mounting holes in the chain brackets are 8 3/8"...
  • Page 10: Wiring And Hookup

    WARNING W I R I N G A N D H O O K U P WARNING WARNING To reduce the risk of SEVERE INJURY or DEATH: • DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. We recommend that •...
  • Page 11: Input Commands 1-8 (3-Button Control Station)

    INPUT COMMANDS CONNECTIONS Terminal 5, Safety - Safety edge(s) and safety loop input. This function will make the gate reverse and go back to the open (Use common and normally open contacts from devices position if it was closing. Input is for all NORMALLY OPEN connected to these inputs) contact safety devices.
  • Page 12: Accessory Connections

    ACCESSORY CONNECTIONS These terminals will provide battery backed power to 24 Vdc devices and are located at the bottom of the electronic control board at J4 terminals 1 and 2. Terminal 1 is 24 Vdc (+) and number 2 is 0 Vdc (-). Peripheral CLASS 2 low voltage devices FIGURE 1 that require 24 Vdc power maybe connected here (500 ma.
  • Page 13: T I M E R S A N D M O D E S E L E C T I O N S S 1 & S 2

    T I M E R S A N D M O D E S E L E C T I O N S S 1 & S 2 FAST RUN TIMER - SWITCH PACK S1 (1-5) To change the FAST SPEED run timer, set the dip switches to add Seconds - - 1 - - 2 - -...
  • Page 14: Adjustments

    A D J U S T M E N T S RIGHT OR LEFT HAND OPERATION RIGHT HAND OPERATION UNIT SHIPS AS RIGHT-HAND OF FUSE Method 1: No longer used as of August 16, 2003. The S1-7 AUX. LIMITS switch will be redefined. Green (Open &...
  • Page 15: Receiver

    R E C E I V E R WARNING NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of WARNING WARNING this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery.
  • Page 16: Operation And Maintenance

    (Set with R63, shown on the • Disconnect ac power at the fuse box. Control Board Layout page). • Disconnect dc power at the battery connection. • Replace batteries with LiftMaster P/N MBAT batteries. Replace in pairs. BATTERY DISPOSAL BATTERY MAINTENANCE / TESTING The batteries are maintenance free.
  • Page 17: Troubleshooting

    T R O U B L E S H O O T I N G BATTERY CHECKOUT WARNING WARNING WARNING When the batteries become weak the gate will begin to run noticeably slower. (NOTE: Batteries should only be checked when To prevent possible SERIOUS INJURY or DEATH from you are sure they have had adequate time to fully charge.) Turn electrocution or fire, BEFORE proceeding...
  • Page 18: Suggested Loop Sensor Locations

    SU GGE ST E D LOOP SE N S O R L OC A T IO N S FREE EXIT ON VEHICLE APPROACH Gate will open when sensed by open loop and then close once all loops are cleared if the close timer is on. Close input can be used to close gate before timer expires (Figure 1).
  • Page 19: Control Board Layout

    C O N T R O L B O A R D L A Y O U T Open Gate Inputs - Reader, Push Button Aux Open / Reset (Pulse Open/Close) Safety Loop Input Close Gate Input - Close Loop Back Away - Free Exit Loop Shadow Loop Commons - 0 Vdc...
  • Page 20 R E P A I R P A R T S 1/2 HP FRONT VIEW SIDE VIEW REAR VIEW INDIVIDUAL PARTS ITEM PART # DESCRIPTION MS001 Controller - CPU MS003 1/2 HP High Torque Motor 24 Vdc MS005 Gear Reducer 10:1 MS006X 1/4"...
  • Page 21 A C C E S S O R I E S 371LM ® Security✚ Single Button Remote Control : Wiring Harness: For the A24. Includes visor clip. Heater Option: 150 watt with thermostat MA201 ® Security✚ 3-Button Remote Control : 373LM MBAT Replacement Battery (1):...
  • Page 22: Safety Accessories For Secondary Entrapment Protection

    OUR LARGE SERVICE ORGANIZATION SPANS AMERICA INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE. SIMPLY DIAL OUR TOLL FREE NUMBER: 1-800-528-2806 www.liftmaster.com WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART NAME • MODEL NUMBER ADDRESS ORDERS TO: THE CHAMBERLAIN GROUP, INC.
  • Page 23 L I M I T E D W A R R A N T Y LIFTMASTER 2 YEAR LIMITED WARRANTY 10 YEAR CORROSION/PERFORATION LIMITED WARRANTY ON COVER AND CHASSIS The Chamberlain Group, Inc. (“Seller”) warrants to the first purchaser of this product, for the structure in which this product is...
  • Page 24 INSTALLATION CHECK OFF LIST This Slide Gate operator is installed for use in a Class _____ installation. Each item on this installation check off list should be verified by the installer. _____ Two warning signs securely installed on each side of gate panel (required). _____ 1 or 2 safety photo beams installed, one across each side of gate opening (required).

This manual is also suitable for:

Liftmaster mslxdcbb3Liftmaster mega slide-x

Table of Contents