Bin Thermostat - Routing - Scotsman CME2086 User Manual

Scotsman eclipse cme2086 ice machine: user guide
Table of Contents

Advertisement

Bin Thermostat - Routing

Install the bin thermostat after the ice making
head has been placed on the bin or dispenser.
Note: Dispensers may require special attention to
keep ice or agitator/sweep arm from moving the
thermostat from its installed position. Place the
head on the dispenser and install the thermostat
before connecting refrigerant tubing.
Before starting, remove the left side and front
panels and any baffle in the bin.
1. Locate bin thermostat bulb.
2. Route bulb thru routing tube (located behind the
reservoir).
3. Locate bin thermostat bracket.
4. Carefully position the thermostat bulb on the
bracket (see the diagram on the next page).
5. Fasten the bracket to the bottom of the ice
machine with the two 3-pronged knob head screws
supplied with the unit.
6. Pull back into the ice machine any excess
capillary tubing.
Thermostat
Bulb Routing
Tube
7. Return the baffle to the bin and continue with the
installation.
Note: If the machine is located at an altitude higher
than 2,000 ft., adjust the thermostat by removing
the plastic cover and rotating the adjustment screw
per the table.
Bin Thermostat Altitude Correction Table
CW Turns of Range Screw (under plastic cover)
Feet
2000
4000
6000
Bin
Thermostat
Bulb
September 2003
Page 19
Eclipseä 2000
Turns
Feet
o
55
8000
o
160
9000
o
250
10000
Turns
o
340
o
385
o
405

Advertisement