Service Diagnosis - Scotsman CME2086 User Manual

Scotsman eclipse cme2086 ice machine: user guide
Table of Contents

Advertisement

Service Diagnosis

Problem or Symptom
No ice
* Additional diagnostics for this component are on the following pages
Possible Cause
No power to ice making section
No power to condensing unit
No lights on controller
Unit manually switched off
Power to both sections, controller reset,
but condensing unit does not operate
No water to ice making section, controller
blinking water light twice and repeating
Ice making section has exceeded
maximum freeze time and controller has
shut down the system
Ice making section has exceeded
maximum harvest time and shut down the
system
Bin full light is on but bin is not full
September 2003
Page 41
Eclipseä 2000
Probable Correction
Restore power
Restore power
Check transformer
Push and release the Freeze button, ask
user why it was shut off
Interconnecting control wire
disconnected, reconnect it
Low or high pressure cut outs open,
check system pressures
Restore water supply, check water filters,
reset controller
Check inlet water valve operation
Check water level sensor operation,
including harness between sensor and
controller*
Condenser coils may need cleaning
Check condenser fan blade and motor
Check for excessive air intake
temperatures at condenser coil
Check compressor contactor
Check compressor and starting
components
Check water pump
Check purge valve for leak through
Check vapor inlet valve for leak though
Check ice making section for lime scale
build up, clean as needed
Check condenser by pass valve
Check vapor inlet valve*
Check headmaster
Check ice sensors for cube sensing*
Check inlet water valve for leak through
Check for obstruction in ice delivery chute
Check ice sensors*
Check optional thermostat*