Bin Thermostat Installation

The bin control is a thermostat. It must be field installed
after the ice machine has been placed on the bin.
Before starting, remove the left front panel and any
baffle in the bin.
1. Locate bin thermostat bulb.
2. Route bulb through routing tube (located between the
compressor and the reservoir).
3. Locate bin thermostat bracket.
4. Carefully position the thermostat bulb on the bracket.
5. Fasten the bracket to the bottom of the ice machine
with the two 3-pronged knobs supplied with the unit.
6. Pull back into the ice machine any excess capillary
tubing.
7. Return the baffle to the bin and continue with the
installation.
Bin Thermostat Bulb
Bin
Thermostat
Body
Thermostat Bulb Routing
Tube
Route Bin Thermostat Bulb Into Bin