Direct filling
-
300 ml
400 ml
(Not
available)
Holder
-
joint
Plate
-
Rod
-
Short rod
Piston
-
Holder
-
Holder D
Rubber
-
ring
Rubber ring for holder
Nozzle
-
Nozzle for holder joint B
Holder
-
joint
(as a
cap)
Installing or removing the holder joint
Attach the holder joint and plate by securing the screws firmly. To
remove the holder joint, follow the installation procedure in reverse.
► Fig.8: 1. Screw 2. Plate 3. Holder joint
Installing or removing the rod and piston
1.
Insert the rod from the rear side of the tool with its
teeth facing down.
► Fig.9: 1. Rod
2.
Attach piston to the screw.
► Fig.10: 1. Screw 2. Piston 3. Rod
To remove the rod and piston, follow the installation
procedure in reverse.
Installing or removing the holder
CAUTION:
Secure the holder to the holder
joint firmly. Otherwise the holder may come off
during operation and may cause an injury.
To install the holder, turn it clockwise firmly until it stops
while holding the holder joint. To remove the holder,
follow the installation procedure in reverse.
► Fig.11: 1. Holder 2. Holder joint
600 ml
800 ml
(Not
available)
-
Holder joint B
-
Plate
-
Long rod
-
Piston C
-
Holder B
-
joint B
-
-
Holder joint B

OPERATION

CAUTION:
Do not use solid caulking material.
Be sure to remove the solid caulking material
before the installation. Solid caulking material may
cause malfunction or personal injury.
NOTICE:
Make sure the attachment parts are
correct by referring the section for the parts
preparation. Using improper parts may cause leak-
age or tool breakage.
NOTICE:
Always keep the rod and piston clean.
Adhered caulk may damage the tool.
Using cartridge
Preparing cartridge for use
1.
Cut the tip of the cartridge nozzle so that the
suitable amount of caulking material which you want to
feed.
► Fig.12: 1. Nozzle
2.
Make a hole on the protective film with the tip of
the nozzle.
► Fig.13: 1. Nozzle
3.
Attach the nozzle to the cartridge.
NOTICE:
Be sure to check the cartridge for
damage before installation. Using the damaged
cartridge may cause malfunction.
Installing cartridge to holder A
1.
Pull the rod handle backward slowly until it stops.
► Fig.14: 1. Rod handle
2.
Insert the cartridge into the holder as shown in the
figure.
► Fig.15
3.
Push the rod gently until the piston touches the
bottom of cartridge.
To remove the cartridge, pull the rod backwards until it
stops, then lift out the cartridge.
Installing cartridge to other than
holder A
1.
Pull the rod handle backward slowly until it stops.
► Fig.16: 1. Rod handle
2.
Insert the cartridge into the holder.
3.
Attach the holder joint (as a cap) by turning it
firmly while holding the holder.
► Fig.17: 1. Holder 2. Cartridge 3. Holder joint (as a
cap)
4.
Push the rod gently until the piston touches the
bottom of cartridge.
To remove the cartridge, follow the installation proce-
dure in reverse.