(PFH), the feedback DO1 need not be used. All safety-relevant errors that can occur in the SM100 result in the safe state. Faults have been excluded for protected cables (according to DIN EN ISO 13849-2:2008-09 and DIN EN 61800-5-2:2008-04). This applies to cables which are protected by a cable duct and installed inside the control cabinet.
Page 2
-value: 3.00x10 1 / hour SM100: PFH -value: The SM100 does not contribute to the probability of failure on demand. Therefore, it need not be considered for the calculation. Result: The PFH -value of the entire safety circuit is 3.91 x10 1 / hour.
Page 3
Since the encoder is used to monitor the ramp now, it needs to be considered in the evaluation of the safety characteristics. Connection diagram (section): 24VDC E94AxHExxxx Start X12 X11 Not-Halt/ Emergency stop SM100 E94AYAB SMX 11 041715023 Doc. ID 200909213 Page 3 out of 5 Doc. version Date 19.07.2019...
Page 4
Speed encoder: IG 1024-5V-V3: 2.41x10 1 / hour SM100: PFH -value: The SM100 does not contribute to the probability of failure on demand. Therefore, it need not be considered for the calculation. Result: The PFH -value of the entire safety circuit is 6.32 x10 1 / hour.
Page 5
The safety instructions contained in the technical documentation must be observed. Using the examples does not exempt the user from careful project planning. For possible damages and consequential damages Lenze assumes no liability to the extent permitted by law. Copyright 2019 Lenze Automation GmbH Doc.