When T
T
-2
, compressor outdoor/indoorfan will stop.
amb
set
In this mode, the 4-way valve won't power on, the temperature range is 16
Compressor
Outdoor Fan
7.1.2.2.2 Protection Function

Antifreezing protection

If the anti-freezing protection is detected, compressor,outdoor fan stop to run, indoor fan runs at low fan speed; When anti-
freezing is eliminated and compressor had stopped 3mins, the whole unit will back to original running state. When it isfit for the dry
mode running for 6mins and stop running for 4mins, and system anti-freezing protection is detected, thatthe compressor, outdoor
fan stop running, indoor fan runs at low fan speed, when anti-freezing is eleminated and compressorhad stopped for 4mins, that
will back to original running status.
7.1.2.3 Heating Model
7.1.2.3.1
Heating Running Condition and procedures
If T
T
+2
, Heating mode will act, compressor, outdoor fan and 4-way valve will run, but indoor fan will run after 3minutes
amb
set
delay.
If Tset+2
T amb T set +4
the setting temp. range:16
~30
If Tamb>Tset+4
, compressor , outdoor fan stop running, the 4-wayvalve is power on, indoor fan will stop after 60s
In this mode, the 4-way valve will be powered on, the setting temp. range:16 ~30
7.1.2.3.2
Defrosting Condition and procedures
If frost is detected with the condenser, the system enters defrost mode.In this case, the compressor goes on running, outer fan,
4-way valve and inner fan stop running, the running indicator flash; If Swing is started, that the swing motor will stop torun at the
same time. After the condenser is detected with defrost completed, the outer fan, four-way valve will start torun at the same time,
indoor fan will go into running after a delay of 3mins. The swing motor will resume to run after indoorfan is running, compressor
keeps on original running mode, the running indicator stops flashing.
All manuals and user guides at all-guides.com
amb
SET
SET
Min.
Indoor Fan
Seeting Fan Speed
Low Fan Speed
Running
Compressor
Outdoor Fan
Indoor Fan
, the unit will keep running in the original mode. In this mode, the 4-way valve will be powered on,
.
set
set
amb
Min.
Min.
Compressor
Outdoor Fan
Min.
Indoor Fan
Setting Fan Speed
4-way valve
Running
~30
.
Cooling
Dehumidifying
Stop
Min.
Min.
Min.
Stop
During anti-freezing
Min
Low Fan Speed
Running
Stop
.
Stop Heating
Original Running State
Start Heating
Min.
Min.
Setting Fan Speed
Stop
10