7
7 7 7 7 7 . . . . . 1 1 1 1 1
Remote Controller Function Manual
7.1.1 Temperature Parameter
The room set temperature (Tset)
The room ambient temperature (Tamb)
7.1.2 System Fundamental functions
7.1.2.1 Cooling mode
If T
T
+1
, COOL mode will act, the compressor and the outdoor fan will run, the indoor fan will run at the setting speed.
amb
set
If T
T
- - - -
1
, Compressor and outdoor fan will have a delay of 15 seconds and stop, indoor fan will run at the setting speed
-
amb
set
If T
-1
T
T
+1 , the unit will keep running in the old mode.
set
amb
set
In this mode, the 4-way valve will not power on, the setting temp. range:16
set
set
Compressor
Outdoor Fan
Indoor Fan
7.1.2.1.2 Protection Function
Anti Freezing Protections
When the system tested anti-freezing protection, the compressor will stop, the outdoor fan will delay 15 seconds and stop running .
Over Current protection
When the system is tested, the compressor will stop, the outdoor fan will delay 15 seconds and stop running. The indoor fan will
run at the set speed. When antifreezing protection is eliminated and compressor has stopped for 3min, the system will resume
operation.
7.1.2.2 Dry Mode
7.1.2.2.1 The condition and processes of dehumidifying
When Tamb
Tset+2
, Dry and Cooling modes will act,compressor, outdoor fan will run at setting fan speed.
When Tset-2
Tamb
Tset+2
will stop running, outdoor fan will delay 15s and stop. 3.45 mins later, compressor, outdoor fan and indoor fan motor restart
All manuals and user guides at all-guides.com
amb
Min.
Min.
Setting Fan Speed
Running
During anti-freezing
Compressor
Outdoor Fan
Indoor Fan
Setting fan speed
Running
, Dry mode will act, at this time indoor fan runs at low fan speed,compressor will run 6mins and
~30
.
Start Cooling
Original Running State
Stop Cooling
Min.
Stop
Min.
Stop
9