Warranty ....19 ® labeled product NERGY As an E ® partner, GE has NERGY determined that this product meets the E ® guidelines for NERGY energy efficiency.
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury. SAFETY PRECAUTIONS Use this appliance only for its intended If the receptacle does not match the plug, purpose as described in this Owner’s the receptacle must be changed out by a...
WARNING! EXTENSION CORDS CAUTION: DO NOT use an extension cord with any of the 230/208 volt models. READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS...
About the controls on the air conditioner—models with touch pads. Lights next to the touch pads on the air conditioner control panel indicate the selected settings. Light indicates the unit is in the temperature or The display always shows the room delay time Set mode.
Page 5
Do Not Operate in Freezing Outdoor Conditions This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions. Cool Mode Use the Cool mode at Low, Med, High or Auto Fan Cooling Descriptions Speed for cooling.
About the controls on the air conditioner—models with control knobs. Features and appearance will vary. MODE TEMP High High Coolest Cool Cool Cool MODE CONTROL TEMPERATURE CONTROL Controls The air conditioner controls are located behind the TEMP Control control panel door. Press to open and close the door. The TEMP control is used to maintain the Mode Control room temperature.
Additional controls. ge.com Vent Control The vent control is located above the control panels. When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some outside air is let into the room.
Care and cleaning of the air conditioner. Grille and Case Turn the air conditioner off and remove the To clean, use water and a mild detergent. Do not plug from the wall outlet before cleaning. use bleach or abrasives. Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly.
Installation Air Conditioner Instructions Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com BEFORE YOU BEGIN CAUTION: Do not, under any circumstances, cut or remove the third (ground) prong from the Read these instructions completely power cord. and carefully.
Window Installation Instructions PARTS INCLUDED Window (Appearance may vary) sash seal Left accordion panel Foam top window gasket mounting rail Right accordion panel V-support (2) Window locking bracket (2) Bolt (2) & nuts (2) Type A (6) Type B (4) Type C (7) Type D (6) Type E (4)
Window Installation Instructions WINDOW REQUIREMENTS REMOVE THE AIR CONDITIONER FROM THE CASE • These instructions are for a standard double-hung window. You will need to Remove the locking screw and locking modify them for other types of windows. bracket from the lower frame. Save to reinstall later.
Page 12
Window Installation Instructions PREPARE THE CASE INSTALL THE CASE IN THE WINDOW Install the top mounting rail with 4 type B screws from the inside of the case. Carefully slide the case into the window and center the case. Lower the window behind Top mounting rail the top mounting rail.
Page 13
Window Installation Instructions INSTALL THE CASE INSTALL SUPPORT BRACKETS IN THE WINDOW AND THE FOAM TOP WINDOW (cont.) GASKET Use a wood block (obtained locally) between the leveling bolts and the wall if the wall is Drill pilot holes and attach the support weak or if the weight of the air conditioner brackets with two type D screws, one on falls between the studs in the wall.
Window Installation Instructions INSTALL THE AIR CONDITIONER INSTALL THE AIR CONDITIONER IN THE CASE IN THE CASE (cont.) Make sure the ground Pull the coiled power cord from its shipped wire is off to the side position in the air discharge area. Attach and slide the air the front grille frame to the case by inserting conditioner into the...
Through-the-Wall Installation Instructions—Optional IMPORTANT The case may be installed through-the-wall (cont.) in both existing and new construction. Secure with 14 wood screws anchored at Read completely, then follow step-by-step. least an inch into the wall support structure. NOTE: Except for the V-support NOTE: Drill pilot holes, if necessary, for assemblies (included), obtain all materials proper installation.
Troubleshooting Tips. Troubleshooting Tips. Save time and money! Review the chart below first and you may not need to call for service. Problem Possible Causes What To Do Air conditioner • Make sure the air conditioner plug is pushed completely The air conditioner does not start is unplugged.
Page 17
You can rest easy, knowing that all your valuable household products are protected against expensive repairs. 800.626.2224 Place your confidence in GE and call us in the U.S. toll-free at for more information. *All brands covered, up to 20 years old, in the continental U.S.
General Electric Company Louisville, KY 40225 FAILURE TO COMPLETE AND RETURN THIS CARD DOES NOT DIMINISH YOUR ge.com WARRANTY RIGHTS. For information about GEA’s privacy and data usage policy, go to ge.com and click on “Privacy Policy” or call 800.626.2224.
Page 19
Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this limited one-year warranty, GE will also provide, free of charge, all labor and related original purchase service to replace the defective part.
Contact Us ge.com If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations GE Appliances, Appliance Park...