Electric connection
Dryers must be electrically grounded by a separate #14 or larger green wire from the grounding terminal within the
Service Connection Box, to a cold water pipe. In all cases, the grounding method must comply with local electrical
code requirements; or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or
the Canadian Electrical Code, CA C22.1.
See wiring diagram furnished with dryer. Do not change wiring without consulting the factory, as you may void
the factory warranty. DO NOT CONNECT THE DRYER TO ANY VOLTAGE OR CURRENT OTHER
THAN THAT SPECIFIED ON THE DRYER RATING PLATE. (Wiring diagram is located on rear wall of dryer.)
All panels must be in position before operation of dryer.
G
3 X 380-415 + N
3 X 208-240V
208-240V
PE
L1 L2 L3 N
The connection needs to be made in the wiring box at the back. Open the coverplate
(G) in order to reach the connection clamps.
The connection cable needs to be brought in through the opening on the side of the
wiring box.
It is necessary to ground the dryer for your personal safety and to ensure a good
operation.
115 and 208-240 V - 1 ph
The mains wires (Ll) and (L2) should be connected to the 2 left blocks and the yellow/
green grounding wire (PE) should be connected to the grounding block.
208-240 and 480 V - 3 ph
The 3 mains wires (L1), (L2) and (L3) should be connected to the 3 left blocks and
the yellow/green grounding wire (PE) should be connected to the grounding block.
380-415V - 3 ph
The 3 mains wires (L1), (L2) and (L3) should be connected to the 3 left blocks, the
blue neutral (N) should be connected to the right block and the yellow/green
grounding wire (PE) should be connected to the grounding block.
«Attention. Lors des opérations d'entretien
des commandes, ètiqueter tous les fils avant
de les dèconnecter. Toute erreur de câblage
peut être une source de danger et de panne»