120 and 170 Pound Tumblers Refer to Installation manual for full instructions. 3-09-71R6 October 2011 On-Premise Planning Handbook Starting Serial No. 0907003062 Laundry TMB1268C TMB1268C...
Specifications and Dimensions Specifications Noise level measured during operation at operator position of 3.3 feet (1 meter) in front of machine and 5.2 feet (1.6 meters) from floor. Cylinder Size: Inches (mm) Cylinder Capacity dry weight: Pounds (kg) Cylinder Motor Horsepower Fan Motor Horsepower Air Outlet Diameter: Inches (mm)
Tumblers – 120 and 170 120 Pound Tumbler Dimensions and Exhaust Outlet Locations Models 31.38 in. 32.5 in. 120L/N/E (797 mm) (826 mm) 31.38 in. 32.5 in. 120S (797 mm) (826 mm) Refer to Position and Level the Tumbler to temporarily reduce the heights of these models. Models 63.45 in.
Tumblers – 120 and 170 Installation Pre-Installation Inspection Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered.
Tumblers – 120 and 170 Tumbler Enclosure To reduce the risk of severe injury, clearance of tumble dryer cabinet from combustible construction must conform to the minimum clearances. NOTE: Shaded areas indicate adjacent structure. 0.5 in. (13 mm) recommended between machines for removal or installation. Allow 2-4 in.
Exhaust Requirements WARNING A drying tumble dryer produces combustible lint. To reduce the risk of fire, the tumble dryer must be exhausted to the outdoors. To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust tumble dryer air into a window well, gas vent, chimney or enclosed, unventilated area such as an attic wall, ceiling, crawl space under a building, or concealed...
Tumblers – 120 and 170 NOTE: Exhaust ducts must be constructed of sheet metal or other noncombustible material. Such ducts must be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 0.0195 inches (0.495 mm) thick. Local codes may require additional thickness.
Page 15
TMB2361N TMB2361N Removable strip of panel in framing wall to permit removal of tumbler from framing wall Partition or bulkhead Minimum distance between exhaust opening and roof, ground or other obstruction: 36 in. (914 mm) 2 in. (51 mm) minimum clearance on both sides of duct Exhaust airflow –...
Tumblers – 120 and 170 Manifold Venting While it is preferable to exhaust tumblers individually to the outdoors, a main collector duct may be used if it is sized according to Figure 4 and Figure 5. This illustration indicates minimum diameters, which should be increased if the collector length exceeds 14 feet (4.3 meters) and two 90°...
Electrical Requirements Refer to Table 5. NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline only. Electrical connections should be made only by a qualified electrical contractor in accordance with all applicable local and national requirements.