IPSO 170 Planning Manual

IPSO 170 Planning Manual

120 and 170 pound tumblers

Advertisement

120 and 170 Pound Tumblers
Refer to Installation manual for full instructions.
4-08-45R4
June 2011
Through Serial No. 0907000048
On-Premise
Laundry
Planning
Handbook
TMB1268C
TMB1268C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 170 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IPSO 170

  • Page 1 120 and 170 Pound Tumblers Through Serial No. 0907000048 Refer to Installation manual for full instructions. 4-08-45R4 June 2011 On-Premise Laundry Planning Handbook TMB1268C TMB1268C...
  • Page 2: Table Of Contents

    All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Tumblers – 120 and 170 ... Introduction... Model Identification ...
  • Page 3: Introduction

    Tumblers – 120 and 170 Introduction Model Identification IPD120G2-IT120L 120 Pound IPD170G2-IT170L 170 Pound Includes models with the following control suffixes RD – reversing DMP OPL © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 4-08-45 TMB1268C...
  • Page 4 Tumblers – 120 and 170 120 POUND TUMBLER Serial Plate Multiply 0.252 1055 Inch 25.4 Inches W.C. 0.036 Inches W.C. 0.249 lb./inch (psi) 6.895 28.32 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Conversion Table To Obtain...
  • Page 5: Specifications And Dimensions

    3/4 in. NPT 300,000 (316) Steam Models 1375 (625) 3/4 in. NPT inlet 3/4 in. NPT outlet 11.7 (405,000) Tumblers – 120 and 170 170 Pound 66 dBA 50.75 x 42.5 (1289 x 1080) (77.1) 0.75 (300) (0.8) 2450 (1156)
  • Page 6: 120 Pound Tumbler Dimensions And Exhaust Outlet Locations

    Tumblers – 120 and 170 120 Pound Tumbler Dimensions and Exhaust Outlet Locations Models 31.38 in. 32.5 in. 120L/N (797 mm) (826 mm) 31.38 in. 32.5 in. 120S (797 mm) (826 mm) Refer to Position and Level the Tumbler to temporarily reduce the heights of these models.
  • Page 7: 170 Pound Tumbler Dimensions And Exhaust Outlet Locations

    170 Pound Tumbler Dimensions and Exhaust Outlet Locations Models 33.86 in. 32.5 in. (860 mm) (826 mm) 170L/N/S Refer to Position and Level the Tumbler to temporarily reduce the heights of these models. Models 42.38 in. 170L/N/S (1076 mm) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 8: Electric And Gas Connection Locations For Gas Models

    Tumblers – 120 and 170 Electric and Gas Connection Locations for Gas Models 120L/N Models 120L/N Non-CE 170L/N 120L/N 170L/N NOTE: These figures are approximate dimensions only. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Electrical Connection 27.63 in.
  • Page 9: Electric And Steam Connection Locations For Steam Models

    120S 27.63 in. (702 mm) 170S 31.12 in. (790 mm) 120S 19.69 in. (500 mm) 170S 23.18 in. (589 mm) Tumblers – 120 and 170 170S 13.375 in. 82.75 in. (340 mm) (2102 mm) 15.25 in. 88 in. (387 mm) (2235 mm) 13.125 in.
  • Page 10: Installation

    Tumblers – 120 and 170 Installation Pre-Installation Inspection Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident, have the carrier note the condition...
  • Page 11: Tumbler Enclosure

    24 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes 0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 4-08-45 WARNING Figure 1 Tumblers – 120 and 170 W056 TMB2020N TMB2020N...
  • Page 12: Exhaust Requirements

    Tumblers – 120 and 170 Exhaust Requirements WARNING A drying tumbler produces combustible lint. To reduce the risk of fire, the tumbler must be exhausted to the outdoors. To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust...
  • Page 13: Individual Venting

    2.4 m (7.87 ft.) as required to meet UL2158, clause 7.3.2A. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 4-08-45 Tumblers – 120 and 170 Duct Equivalent Length of Diameter Rigid Straight Duct 6 in.
  • Page 14 Tumblers – 120 and 170 Removable strip of panel in framing wall to permit removal of tumbler from framing wall Partition or bulkhead Minimum distance between exhaust opening and roof, ground or other obstruction: 36 in. (914 mm) 2 in. (51 mm) minimum clearance on both sides of duct Exhaust airflow –...
  • Page 15: Manifold Venting

    © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 4-08-45 Tumblers – 120 and 170 NOTE: Never connect a tumbler duct at a 90° angle to the collector duct. Refer to Figure 3. Doing so will cause excessive back pressure, resulting in poor performance.
  • Page 16 Tumblers – 120 and 170 NOTE: Where the exhaust duct pierces a combustible wall or ceiling, the opening MUST be sized per local codes. Duct Station © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT ONE MANIFOLD ASSEMBLY...
  • Page 17 42 in. (1067 mm) 45 in. (1143 mm) 47 in. (1194 mm) 49 in. (1245 mm) 51 in. (1295 mm) Table 4 Tumblers – 120 and 170 TMB2018N Outlet Duct Diameter 45° Typical 170 Pound 12 in. (305 mm) Duct 17 in.
  • Page 18: Electrical Requirements

    Tumblers – 120 and 170 Electrical Requirements Refer to Table 5. NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline only. Electrical connections should be made only by a qualified electrical contractor in accordance with all applicable local and national requirements.

Table of Contents