Cadel RIVERIDRO 16 T2 Installer Manual page 28

Pellet thermostove
Hide thumbs Also See for RIVERIDRO 16 T2:
Table of Contents

Advertisement

8.11.2 System with: direct pellet stove and room probe or external thermostat** (optional) with external DHW
production controlled by external thermostat (optional)
All activities relating to electrical connections in the electronic board must be carried out by
authorised personnel.
** If the external thermostat is used, activate the "EXT THERMOSTAT" function on the control panel and con-
nect it directly to the electronic board (see electrical system below).
Adjustable setting
SETTING
ROOM TEMP.
WATER TEMP.
DHW TEMP
SEASON
AUTO ECO
Parameters to set
Hydraulic diagram
LEGEND
28
new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2
VALUES
5°C - 35°C
30°C - 80°C
75°C
WINTER (summer may be activated)
OFF (with winter setting)
ON (with summer setting, cannot be deactivated)
SETTING
CONFIGURATION
Fig. 66 - Configuration 2
Fig. 66
1
Anti-condensation valve
2
External thermostat
3
Room probe
VALUES
2

Advertisement