Ulpg Installation - Capital PRECISION Outdoor ACG40RBI.1N/L Use And Care Manual

Table of Contents

Advertisement

Gas Cylinder Safety Information
This appliance is designed to be used with a gas cylinder not exceeding 9KG Capacity. The Gas cylinder
must be constructed and marked in accordance with specifications and certified to AS 2469 for ULP. The
gas cylinder supply valve must be turned off when the appliance is not in use. Gas cylinders must be stored
outdoors, out of reach of children and must not be stored in a building, garage or any other enclosed area.
The gas cylinder used must incorporate a safety collar to protect the valve assembly
When disconnecting and removing the gas cylinder for the purpose of refilling, always observe the following
procedure.
Ensure that all gas control valves on the appliance and the gas cylinder are turned off before disconnecting
the gas line from the cylinder.
Do not smoke or use a naked flame near the appliance or gas cylinder while disconnecting the gas line
between the appliance and gas cylinder.
Remove the gas cylinder from the enclosure before disconnecting the gas line from the appliance.
Tighten all connections before placing the gas cylinder back in its enclosure.
The Gas Leak Testing Procedure should be conducted every time the gas cylinder is refilled and
reconnected to the appliance - before using the appliance.
Regulator connection (Fig 1 & 2)
1. Check that all control knobs are in the 'Off' position.
2. Make sure the cylinder valve is off by turning the valve knob clockwise.
3. Remove the protective cap from the cylinder if present.
4. Leak test the connection with a soapy water solution (See Gas Leak Testing Procedure) Hose and
regulator replacement must be a genuine part specified for this appliance and is obtainable from Arisit Parts
1300762219
You should connect your barbeque to a 9 kg gas cylinder, which can be refilled or swapped at petrol stations
or your place of purchase when empty. Before connecting the cylinder, inspect the hose, fittings and rubber
seals. If there is any sign of splitting or wear, have the hose replaced.
If you have a gas safety gauge, ensure this is connected to your bottle according to the manufacturer's
instructions. Now connect the regulator end of the hose to the gas bottle. You won't need a spanner here.
Just turn the fitting in an anticlockwise direction and hand tighten as much as you can. This should seal it
sufficiently. Ensure the gas bottle is upright at all times. Conduct a leak test before use - see the next section.

ULPG INSTALLATION

10

Advertisement

Table of Contents
loading