Remote Start Control - Prestige APS997ZLR Installation And Reference Manual

Vehicle security/remote start system
Table of Contents

Advertisement

Detailed Descriptions: Setup Options
Remote Start Control (Bank 3)
Feature Bank 3
1 Defrost Output
2 RS Start No�fica�on
3 RS Run�me
4 RS Parking Lights
5 Engine Confirma�on
6 Voltage Level
7 Igni�on 2 Output
8 Igni�on 3 Output
9 Accessory Output
10 Transmission
11 Max Crank Time
12 Diesel Delay
13 Temperature Start
14 Crank Dura�on
15 RS Shock Override
16 Turbo Timer
17 Start Ac�va�on
18 RS Lock Func�on
19 Factory Disarm Output
20 Addi�onal Unlock Pulse
Feature 1: Defrost Output Duration
Function: Set the Defrost output to activate for a set time.
Setting Choices:
Option 1 - Output pulses for 1 second.
Option 2 - Output stays on for 10 minutes.
Option 3 - Output stays on for the duration of the Remote Start Runtime.
Feature 2: Remote Start Notification
Function: Set remote start activation confirmation beeps on or off.
Setting Choices:
Option 1 - On - System emits an audible beep when remote start is activated.
Option 2 - OFF -System remains silent when remote start is activated.
Feature 3: Remote Start Run Time
Function: Set the maximum remote start run time if the vehicle is not entered after activation.
Setting Choices:
Option 1 - Engine will run for 15 minutes.
Option 2 - Engine will run for 20 minutes.
Option 3 - Engine will run for 45 minutes.
Option 4 - Engine will run for 60 minutes.
Option 5 - Engine will run for 5 minutes.
Option 6 - Engine will run for 10 minutes.
Feature 4: Remote Start Parking Light Duration
Function: Set parking light output to turn on or flash lights during remote start.
Setting Choices:
Option 1 - Lights remain on during remote start.
Option 2 - Lights flash during remote start.
APS997ZLR_RevA_05/22
1 Chirp
2 Chirp
Pulsed
10min
ON
OFF
15min
20min
Steady
Flashing
Tach
Voltage
>0.5v B4 Start
<0.5v B4 Start
Ignition
Accessory
Ignition
Accessory
Accessory
Igni�on
Auto
Manual
0.8sec
1.0sec
OFF
Diesel 5
OFF
14F
Averaging
Preset
Shunt until Clear
Shunt RS Cycle
OFF
3min
Two Press
One Press
No Change
UL Before L A�er
Single Pulse
Double Pulse
No Pulse
IGN, ACC, GWR
See page 23 for Programming Instruction.
Op�ons
3 Chirp
4 chirp
RS Run�me
45min
Data
Start
Start
Start
1.5sec
Diesel 10
Diesel 15
5F
Shunt From TX
5min
Three Press
UL Before Start
Lock A�er Start
350ms
IGN,ACC,GWR,PASD
5 Chirp
60min
5min
Hybrid
2.0sec
3.0sec
Diesel 20
0F
-4F
10min
500ms
800ms
6 Chirp
10min
4.0sec
Diesel 30
-14F
Same As Bank 2, F1
13

Advertisement

Table of Contents
loading

Table of Contents