The selectable features can be set manually as explained below, or with the RF feature programmer.
To set features using the RF programmer, follow the instructions packaged with the programmer.
Factory default settings are indicated by bold text.
Note : The method of manual override can either be selected to operate from the valet switch or operate as custom code.
Be certain to place a check mark indicating the method used in the box located on the last page of the owner's manual.
NOTE: Keyless Entry Models with no horn output will Flash the Parking Lights instead of chirp where chirp is indicated.
Also, No data will be indicated if a feature is not available for a particular model. The unit will enter the feature but no selection will be available.
RF Programmable Feature Bank 1 Is For Transmitter Programming See Transmitter Programming Guide.
RF Programmable Features Bank 2 Is Alarm Selectable Features:
Feature Selection
1 Chirp
1st DoorL/UL
1 Sec.
2nd Accy Lock
Not Available
3rd Accy. UL
Not Available
4th Headlights
Not Available
5th Passive Locks
Not Available
6th Pass/Act Arm
Not Available
7th Siren/Horn
Not Available
8th Horn Chirp
Not Available
9th O/R Method
Not Available
10th 2 Step U/L
Not Available
11th Chp Del Tx
Not Available
12th Voltage/Hd Wire
Not Available
13th Trigger Circuits
Not Available
14th Lock/Unlock Poll
Not Available
15th Aux Ch 5 Sel
Not Available
16th Aux Ch 6 Sel
Not Available
17th Aux Ch 7 Sel
Not Available
18th Trigger Delay
Not Available
When using the RF programmer, enter the program mode as follows:
Turn the ignition on
Press and release valet switch 3 times
turn ignition off then on
Press and hold valet switch for 5 seconds
Siren and or lights chirp/flash 2 times indicating access to RF feature program mode.
2 Chirps
3 Chirps
4 Chirps
3.5 Sec.
1 Sec L, Dbl. U/L
Dbl L, 1 Sec UL
Model APS-901
Installation Manual
5 Chirps
6 Chirps
Dbl L, Dbl UL
1 S l/350mS ul

Advertisement

Table of Contents
loading

Summary of Contents for Prestige Prestige APS-901

  • Page 1 The selectable features can be set manually as explained below, or with the RF feature programmer. To set features using the RF programmer, follow the instructions packaged with the programmer. Factory default settings are indicated by bold text. Note : The method of manual override can either be selected to operate from the valet switch or operate as custom code. Be certain to place a check mark indicating the method used in the box located on the last page of the owner's manual.
  • Page 2 To program these selectable features; Action Turn ignition on Press and release the valet switch 3 times Within 3 seconds, turn ignition Off Then On This Action Accesses Feature Bank 2 Alarm Selectable Features First Press and release the valet switch 1 time Press transmitter Lock button to change Press transmitter Lock button to change Press transmitter Lock button to change...
  • Page 3 To exit program mode, turn ignition off, or press and release valet switch. RF Programmable Features Bank 3 Is Remote Start Selectable Features: Feature Selection 1 Chirp 2 Chirps 1st Defrost Output Not Available 2nd RF Start Chirp Not Available 3rd Run Time 5 Mins 10 Mins...
  • Page 4 Action Turn ignition on Press and release the valet switch 3 times Within 3 seconds, turn ignition Off, On, Off, On This Action Accesses Feature Bank 3 Remote Start Selectable Features First Press the valet switch one time Press transmitter Lock button to change Second Press and release the valet switch Press transmitter Lock button to change...
  • Page 5: Installation Of The Major Components

    This Remote Start System is designed for use with Automatic Transmission Vehicles Only! The unit provides wait to start input for glow plug pre-heat which will be used for all diesel applications. If this wire is not connected, then the unit will remain in the Gasoline mode setting, which will crank the car when the RF signal is received with no delay.
  • Page 6: Wiring The 6 Pin Main Power Harness

    DO NOT PLUG THE SIX PIN MAIN POWER HARNESS OR THE MULTI PIN INPUT / OUTPUT HARNESS INTO THE CONTROL MODULE UNTIL ALL CONNECTIONS TO THE VEHICLE HAVE BEEN MADE. AFTER SELECTING YOUR TARGET WIRES AS DEFINED BELOW, DISCONNECT THE NEGATIVE BATTERY CABLE FROM THE VE- HICLE BATTERY PRIOR TO MAKING ANY CONNECTIONS.
  • Page 7 SEE NEUTRAL START SAFETY TEST FOR FURTHER DETAILS. BLUE WIRE: Ignition 1 Output Connect this wire to the ignition 1 wire from the ignition switch. This wire will show +12 volts when the ignition key is turned to the to the "ON" or "RUN" and the "START" or CRANK" positions and will have 0 volts when the key is turned to the "OFF"...
  • Page 8 Black wire; see Brown w/ Black tracer wire. BROWN WIRE: Positive Inhibit Input 1 Any time + 12 Volts is applied to the Brown wire, the Remote Starter will stop operating, even if the signal is received from the transmitter.
  • Page 9 This wire provides a + 12 Volt output when the ignition key is turned to the “ON” position, and 0 Volts when the ignition key is “OFF” and when the vehicle is running under the control of the remote starter.
  • Page 10 5. Connect the previously selected resistor from terminal #87 to the second (#2) wire (as shown). NOTE: The above information and following diagram is for the GM VATS system only. For GM PASS LOCK System you will require the Audiovox AS-PASS II Module. General Motors VATS By-Pass Diagram GREEN/ORANGE Wire: Tach Sensor Input This wire will continually monitor the engine tach rate while the unit is under power of the Remote Start module.
  • Page 11: Wiring The 4 Pin Auxiliary Output Harness

    cases will operate properly from one multi coil pack regardless of the number of cylinders. If the vehicle has a single coil unit for each cylinder, it may be necessary to connect this wire to more than one cylinder for proper tach reference.
  • Page 12 2 Pin Transponder Control Output: (Yellow Connector) This output is intended to allow the control of a transponder bypass interface module or transponder bypass relay. The system also allows software selections to control the way in which this output oper- ates, see remote start feature # 10 for setting this output.
  • Page 13: Hood Pin Safety Shut Down

    3. Raise the hood and confirm that the remote start unit shuts down. If the unit fails this test, recheck your pin switch connection to the Gray/Black wire of the Audiovox Remote Start Unit. DO NOT RELEASE THIS VEHICLE TO THE CONSUMER UNTIL YOU CONFIRM THE OPERATION OF THE HOOD PIN SAFETY SHUT DOWN FEATURE.
  • Page 14: Mechanical Neutral Safety Switch Considerations

    The installation required for this application (shown below), indicates the slight reconfiguration of the control switch wiring and the addition of a 4000 series diode. Shown is a typical GM Park/Neutral ECM input circuit. To connect the Audiovox remote start unit to the GM Park / Neutral ECM input: 1.
  • Page 15 E. Connect the cathode (striped) side of a 4002 series diode to this same wire, and connect the (non striped) side to the negative shut down safety wire (Gray / Black) of the Audiovox Remote Start Unit. F. Connect terminal #86 of the relay to a fused +12 volt constant battery source.
  • Page 16: Completing The Installation

    COMPLETING THE INSTALLATION: After you have confirmed the operation of the Audiovox Remote Start unit and tested all the safety features of the system: 1. If you have not done so already, place the red rubber handle cover over the handle of the control switch for ease of identification.
  • Page 17 128-7765 17 of 19...
  • Page 18 THIS PAGE LEFT BLANK INTENTIONALLY 128-7765 18 of 19...
  • Page 19 © 2006 Audiovox Electronics Corp., Hauppauge, NY 11788 128-7765 128-7765 19 of 19...

Table of Contents