Wired Dimming Connections (Optional)
RISK OF ELECTRIC SHOCK OR PRODUCT DAMAGE
• Turn power off before installation, inspection, cleaning or
removal. Follow appropriate lock out/tag out safety procedure.
• This product must be installed in accordance with the
applicable installation code by a person familiar with
the construction and operation of the product and the
hazards involved.
NOTE: Arize Factor dimming allows user to adjust the light output from 0%/10-100%. When set to 0%, the system will enter standby mode,
consuming 0.5-1.5W and LEDs may remain very faintly lit. If 0 light is preferred, switch off the unit via the mains (AC line).
Remove screws
1
Junction Box Cover Removal
• Using a #1 Phillips screwdriver, unscrew the 6
screws on the junction box cover.
• Remove the junction box cover from the junction
box enclosure.
NOTE: Be sure to hold on to the screws, junction box
cover, and gasket for future use.
3A
For Drivers Prior 2021
Dimming
Switch
Driver
Wire Dimming Electrical Connections
3
• 3A - For Drivers Prior 2021
Connect the appropriate wiring to Dim + (0-10V) and
Dim – (0-10V) from driver. Insulate the black-white,
pink and blue-white wires. Follow dimming switch
instructions for rest of connection.
• 3B - For Drivers After 2021
Connect the appropriate wiring to Dim + (0-10V) and
Dim – (0-10V) from driver. Insulate the black-white,
white-purple, and blue-white wires. Follow dimming
switch instructions for rest of connection.
WARNING / AVERTISSEMENT
RISQUE DE CHOC ÉLECTRIQUE OU DE DOMMAGE AU PRODUIT
• Coupez l'alimentation avant l'inspection, l'installation ou la
• Ce produit doit être installé selon le code d'installation
Remove cover
3B
For Drivers After 2021
Dimming
Switch
Driver
désinstallation. Suivez la procédure de sécurité appropriée de
verrouillage/étiquetage.
pertinent, par une personne qui connaît bien le produit et son
fonctionnement ainsi que les risques inhérents.
AC input
To lightbar
2
Wall Dimming Wire Insertion
• Remove the sealed gland in the bottom of the
junction box enclosure, and install an appropriate
Listed ½" NPT fitting rated for the environment into
the open threaded open conduit connection.
• Bring the conductors for the building dimming
network into this fitting.
NOTE: Customer is responsible for the 1/2'' NPT- 14
thread per inch fitting.
Gasket in cover
Junction Box Cover Replacement
4
• Ensure gasket is sitting in place on the inner edge of
the junction box cover.
• Fasten all 6 screws to ensure water tight seal.
NOTE: Be careful not to strip out the junction box
enclosure by over tightening the screws.