Siemens sitrans lr460 Quick Start Manual
Siemens sitrans lr460 Quick Start Manual

Siemens sitrans lr460 Quick Start Manual

4-wire, 24 ghz fmcw radar level transmitter
Hide thumbs Also See for sitrans lr460:

Advertisement

Quick Start Manual July 2007
English
Cesky
Dansk
Deutsch
Español
Français
Italiano
Nederlands
Português
Suomi
Svenska
sitrans
LR460

Advertisement

Table of Contents
loading

Summary of Contents for Siemens sitrans lr460

  • Page 1 Quick Start Manual July 2007 English Cesky Dansk Deutsch Español Français Italiano Nederlands Português Suomi Svenska sitrans LR460...
  • Page 2 DELLSONICS 北京迪妙声科技有限公司 BEJING DELLSONICS SCIENCE & TECHNOLOGY LTD. 公 司 简 介 北京迪妙声科技有限公司(原名北京妙声力科技有限公司) ,位于北京市海淀区中关村 南大街,是与西门子公司德国总部正式签约的西门子过程仪表及分析仪器核心合作伙伴, 也是西门子北方区域规模最大、实力最强的优秀代理商。 公司主营: 一、 西门子-妙声力(Milltronics)系列物位产品:超声波物位计、超声波液位差计、超声波泥水界 面计、超声波明渠流量计、雷达物位计、射频导纳物位计、射频导纳油水界面计、 ;射频导纳物位开关、 音叉式物位开关、阻旋式物位开关;皮带称、固体质量流量计、冲板流量计等。 二、 西门子过程仪表产品:电磁流量计、质量流量计、超声波流量计、 温度变送器、压力变送器、 阀门定位器、气体分析仪等。 三、 德国 UWT 公司的阻旋式料位开关、音叉式料位开关、重锤式料位计等产品。 四、 自行研发生产超声波液位计、温度变送器、压力变送器、数显表及油田专用仪器等产品。 成立于 1954 年的西门子-妙声力公司 是世界公认的超声波物位测量领域 (Milltronics) 的领导者, 全球最大的超声波物位仪表生产厂家, 在超声波、 雷达、 电容技术领域拥有超过 60 项专利,超声波产品的综合性能指标经美国《控制》杂志评比,其综合性能名列全球第一!...
  • Page 3: Safety Guidelines

    FCC and IC Conformity US Installations only: Federal Communications Commission (FCC) rules WARNING: Changes or modifications not expressly approved by Siemens Milltronics could void the user’s authority to operate the equipment. Notes: • This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 4: Installation

    FCC, Industry Canada, European Radio (R&TTE), C-Tick Installation WARNING: SITRANS LR460 is to be used only in the manner outlined in this manual, otherwise protection provided by the equipment may be impaired. Installation shall only be performed by qualified personnel and in accordance with local governing regulations.
  • Page 5 (see design above). Direct SITRANS LR460 so the horn antenna is pointed at an angle perpendicular to the material surface, if possible. (As a guide, aim the beam at a point approximately 2/3 of the way across the tank diameter.) When the desired position is reached, re-tighten the 5 bolts to 15-23 N m (11 to 17 Lbf-ft).
  • Page 6 Loosen the cable gland and push the power cable through until it reaches the terminal strip. SITRANS LR460 HART wiring SITRANS LR460 PROFIBUS PA wiring Go to on page 7 or on page 8 for next steps. Page EN-6 SITRANS LR460 – QUICK START MANUAL 7ML19985QW82...
  • Page 7: Connecting Hart

    Adjust the cable length so that the earth (ground) earth conductor would be last to disconnect if cable terminal is pulled. Tighten the cable gland and check the strain relief (pull and turn). 7ML19985QW82 SITRANS LR460 – QUICK START MANUAL Page EN-7...
  • Page 8: Power Demands

    Note: Power Demands To determine how many devices can be connected to a bus line, calculate the combined maximum current consumption of all the connected devices: 10.5 mA for SITRANS LR460. Allow a current reserve for safety. Bus Termination PROFIBUS PA MUST be terminated at both extreme ends of the cable for it to work properly.
  • Page 9: Connecting Profibus Pa

    (ground) terminal connection at your vessel. Use a cable with a cross-section of 2.5 mm or greater. SITRANS LR460 HART wiring Return to on page 7 to complete LR460 set up. 7ML19985QW82 SITRANS LR460 – QUICK START MANUAL Page EN-9...
  • Page 10: Programming Sitrans Lr460

    SITRANS LR460 only supports SIMATIC PDM version 6.0 with SP2 HF1 (or higher). Note: To set up SITRANS LR460 for a simple application requires only the following settings: • select application type (silo construction) • select operation mode: level, distance or space •...
  • Page 11: Quick Start

    To change a setting, scroll to the desired selection or key in a new value. After modifying a value, press Right ARROW to accept it. The LCD displays the next menu item, the PROGRAM icon disappears, and the rightmost digit flashes to indicate Navigation Mode. 7ML19985QW82 SITRANS LR460 – QUICK START MANUAL Page EN-11...
  • Page 12 Values 1.6 Low Calibration Point (CAL LOW) Distance from Sensor Reference to low calibration point: usually process empty level (See 1.3 Operation for an illustration) Range: 0.0000 to 100.00 m Values Page EN-12 SITRANS LR460 – QUICK START MANUAL 7ML19985QW82...
  • Page 13: Quick Start Wizard Via Simatic Pdm

    In order to save the Quick Start settings it is necessary to enable Apply Changes. YES, NO Options Select YES. SITRANS LR460 is now ready to operate and returns to RUN mode. Communication via HART or PROFIBUS PA Notes: • The Quick Start settings are not independent parameters. The settings are inter- related, and changes only apply when you click Transfer at the end of step 4.
  • Page 14: Step 2 - Application Type

    Launch SIMATIC Manager and create a new project for LR460. Application Guides for setting up HART and PROFIBUS PA devices with SIMATIC PDM can be downloaded from the product page of our website at: https://pia.khe.siemens.com/index.asp?Nr=14655 Open the menu Device – Reset, select Factory Defaults and click OK.
  • Page 15: Hazardous Area Installations

    10. Equipment Marking: The equipment marking contains at least the information on the product label. See product nameplate. 7ML19985QW82 SITRANS LR460 – QUICK START MANUAL Page EN-15...
  • Page 16 For applications that require the purge feature, the user shall implement a means to ensure that combustible dust from the hazardous area cannot enter the purge supply in such a way as to compromise the area classification. Page EN-16 SITRANS LR460 – QUICK START MANUAL 7ML19985QW82...

Table of Contents