Installing/mounting
5.1 Basic safety notes
5.1.1.2

Avoid

• Proximity to high voltage or current wiring, high voltage or current contacts, and to
variable frequency motor speed controllers
• Exposure to direct sunlight. (Provide a sun shield to avoid direct sunlight.)
• Interference to sound path from obstructions (such as rough walls, seams, rungs, etc.), or
from fill path
18
Customer-supplied flange
Ambient temperature surrounding enclosure –40 to +80 °C (–40 to +176 °F)
Device tag (optional)
① Pipe
② Rungs
③ Seams
Compact Operating Instructions, 09/2021, A5E42673704-AE