Download Print this page

Further Information - Hilti DX 351 M&E Manual

Hide thumbs Also See for DX 351 M&E:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Malfunction
The cartridge doesn't fire
The cartridge strip melts
A cartridge detaches itself
from the cartridge strip
10
Disposal
Most of the materials from which Hiltiproducts are manufactured can be recycled. The materials must be
correctly separated before they can be recycled. In many countries, your old tools, machines or appliances
can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative for further information.
11
Manufacturer's warranty
▶ Please contact your local Hilti representative if you have questions about the warranty conditions.
12
C.I.P. test confirmation
The following applies to C.I.P. member states outside the EU and EFTA judicial areas: The Hilti DX 351
has been system and type tested. As a result, the tool bears the rectangular PTB approval mark showing
approval number S 809. Hilti thus guarantees compliance with the approved type.
13

Further information

DX 351 M&E
For more information on operation, technology, environment and recycling, follow this link:
qr.hilti.com/manual/?id=333016&id=332581&id=333017&id=333018
This link is also to be found at the end of the operating instructions, in the form of a QR code.
*333018*
Possible cause
Fastening tool was not pressed
fully against the working surface.
Wrong combination of fastener,
fastener guide, etc.
Fastening tool was pressed against
the working surface for too long.
Fastener driving rate too high (fas-
tening tool overheated).
Fastener driving rate too high (fas-
tening tool overheated).
333018
Action to be taken
▶ Press the fastening tool fully
against the working surface.
▶ Check that the combination of
fastener, fastener guide, etc. is
correct for your application.
▶ Remove cartridge strip and
insert a new cartridge strip
instead.
▶ Fire the fastening tool sooner
after pressing it against the
working surface.
▶ Stop using the tool immediately.
▶ Remove cartridge strips and
allow the fastening tool to cool
down.
▶ Do not exceed the recom-
mended maximum fastener
driving rate (see the section
headed "Technical data").
▶ Stop using the tool immediately.
▶ Remove cartridge strips and
allow the fastening tool to cool
down.
▶ Do not exceed the recom-
mended maximum fastener
driving rate (see the section
headed "Technical data").
English
15

Advertisement

loading

This manual is also suitable for:

Dx 351 mx