8. Installation
Service Manual
power
connection
wire
(2) Remove the wire clip; connect the power connection wire to
the wiring terminal according to the color; tighten the screw and
then fix the power supply wire,power connection wire with wire
clip.(As show in Fig.12)
24K Cool only type:
N(1) 2
yellow-
blue black brown brown blue
green
Outdoor unit connection
24K Heat pump type:
yellow-
blue black brown brown
green
Outdoor unit connection
Note:the wiring board is for reference only, please refer to the actual one.
(3) Adjust the position of upper and lower adjusting baffle; clamp
the connection pipe and drain pipe as firm as possible.
(4) Tighten the screws.
Note:
(1) All wires of indoor unit and outdoor unit should be connected
by a professional.
(2) If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the wire by
yourself.
(3) For the air conditioner with plug, the plug should be
reachable after finishing installation.
(4) For the air conditioner without plug, an air switch must be
installed in the line. The air switch should be all-pole parting
and the contact parting distance should be more than 3mm.
7. Bind up Pipe
(1) Bind up the connection pipe, power cord and drain hose with
the band.(As show in Fig.13)
(2) Reserve a certain length of drain hose and power cord for
installation when binding them. When binding to a certain degree,
separate the indoor power and then separate the drain hose.(As
show in Fig.14)
(3) Bind them evenly.
(4) The liquid pipe and gas pipe should be bound separately at
the end.
indoor unit
Installation and Maintenance
cable-cross
hole
Fig.11
3
L
N
36K:
yellow-
green
N(1)
2
L
N
POWER
blue
black
brown
N(1) 2
3
L
N
Outdoor unit connection
blue
yellow-
green
L
N
POWER
Fig.12
indoor and outdoor power cord
gas pipe
liquid pipe
band
drain hose
Fig.13
Note:
(1) The power cord and control wire can't be crossed or
winding.
(2) The drain hose should be bound at the bottom.
8. Hang the Indoor Unit
3
(1) Put the bound pipes in the wall pipe and then make them pass
yellow-
through the wall hole.
green
(2) Stuff the gap between pipes and wall hole with sealing gum.
(As show in Fig.15)
(3) Fix the wall pipe.
(4) Check if the indoor unit is installed firmly.
Note:
Do not bend the drain hose too excessively in order to prevent
blocking.

8.6 Installation of Outdoor Unit

1. Fix the Support of Outdoor Unit(Select it according to the
actual installation situation)
(1) Select installation location according to the house structure.
(2) Fix the support of outdoor unit on the selected location with
expansion screws.
Note:
(1) Take sufficient protective measures when installing the
outdoor unit.
(2) Make sure the support can withstand at least four times the
unit weight.
(3) The outdoor unit should be installed at least 3cm above the
floor in order to install drain joint.(As show in Fig.16)
(4) For the unit with cooling capacity of 2300W~5000W, 6
expansion screws are needed; for the unit with cooling capacity
of 6000W~8000W, 8 expansion screws are needed; for the
unit with cooling capacity of 10000W~16000W, 10 expansion
screws are needed.
drain hose
connection pipe
indoor power cord
Fig.14
Indoor
Outdoor
Wall pipe
Sealing gum
Fig.15
band
43