Kärcher HD 6/15 C Manual
Hide thumbs Also See for HD 6/15 C:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

HD 6/15 C
9.356-435.0 – Rev. 0

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Kärcher HD 6/15 C

  • Page 1 HD 6/15 C 9.356-435.0 – Rev. 0...
  • Page 3: Table Of Contents

    Antes del primer uso de su Elementos del aparato aparato, lea este manual original, Comprobar en la primera página actúe de acuerdo a sus indicaciones y guárdalo para un uso posterior o para otro 1 Soporte para lanza y accesorios proprietario posterior.
  • Page 4: Indicaciones De Seguridad

    Recomendamos que use la boquilla turbo Indicaciones de seguridad (opcional) para la suciedad más resistente. ¡Antes de la primera puesta en marcha – Dispositivos de seguridad lea sin falta las instrucciones de uso y las instrucciones de seguridad. Válvula de derivación Respetar las normativas vigentes –...
  • Page 5: Puesta En Marcha

    suministra la energía. Es imprescindible que Controle el nivel de grasa el aparato esté conectado con un enchufe a Leer el indicador de nivel de grasa con el la red eléctrica. aparato parado. El nivel de grasa tiene Está prohibido establecer una conexión no que estar por encima de ambas agujas.
  • Page 6: Manejo

    Pone la boquilla deseada en el Valores de conexión, ver datos técnicos. acoplamiento de rosca e atornille en la Conectar la manguera de abastecimien- lanza pulverizadora. to (largo recom. 5-10 m, diámetro mín. Funcionamiento con detergente 1/2“) a la conexión de agua del aparato y a la alimentación de agua (por ejemplo Advertencia al grifo).
  • Page 7: Transporte

    Transporte Desconexión del aparato Colocar el interruptor principal en la Peligro posición "0". ¡Peligro de lesiones y daños! Respetar el Saque el enchufe de la toma de peso del aparato para el transporte. corriente. Para transportar el aparato por trayectos Cerrar el abastecimiento de agua.
  • Page 8: Subsanación De Averías

    Subsanación de averías Antes de cada servicio Comprobar si el cable de conexión está Peligro dañado (peligro por descarga eléctrica), Peligro de lesiones causadas por un aparato encargar al servicio técnico/electricista que se arranque involuntariamente y que cambie inmediatamente el cable de descarga eléctrica.
  • Page 9: Piezas De Repuesto

    Garantía La bomba no es estanca Está permitido perder 3 gotas de agua por En todos los países rigen las condiciones minuto y pueden salir por la parte inferior de garantía establecidas por nuestra del aparato. En caso de fuga de mayor empresa distribuidora.
  • Page 10: Aterramiento Y Plug De 3 Pasadores

    presión esté en la posición apagado. Aterramiento y plug de 3 Para desconectar la lavadora de la alta pasadores presión, nunca la hale por el cable de alimentación, solamente por el plug para no dañarlo. Retire el plug del enchufe antes de efectuar RIESGO DE CHOQUE cualquier mantenimiento o limpieza en la ELÉCTRICO...
  • Page 11: Datos Técnicos

    Datos técnicos Modelo HD 6/15 C Conexión de red Tensión Tipo de corriente 1~50 1~60 1~60 1~50 Corriente Fusible de red (inerte, caro, C) Categora de protección IPX5 Impedancia de red máxima permitida 0.302+j0.189 Alargador máx. 30m Conexión de agua Temperatura de entrada (máx.)
  • Page 12 ARGENTINA BOLÍVIA Karcher S.A Kärcher Bolivia S.R.L Panamericana Km 38.7 - Colectora Este Avenida Banzer s/n edificio el remanso (Esq. Vicente Lopez) - Benavidez (CP 1621) #8500 Santa Cruz Buenos Aires - Argentina Bolivia   +54 (11) 4748 5000 +591 (3) 341611-3427765 COLOMBIA ECUADOR...
  • Page 14: Machine Elements

    Before using your device for Machine elements the first time, read this original Check on the first page manual, act according to its recommendations and keep it for later use 1 Lance and accessories holder or for another owner. 2 Handle, bottom 3 High pressure connection Table of Contents 4 Water connection...
  • Page 15: Safety Recommendations

    Safety recommendations Safety devices Before starting up for the first time, Bypass valve with – please read the usage instructions and pressure switch safety instructions. When the lever of the manual spray gun is Abide by relevant national regulations – released, a pressure switch disengages in force for liquid ejectors.
  • Page 16: Start-Up

    supply company. It is crucial for the device Oil level control to be connected with a plug to the mains. Read the oil level indicator with the Establishing a non-separable connection device stopped. The oil level must be to the power grid is prohibited. The plug is above both needles.
  • Page 17: Management

    Put the desired nozzle on the threaded Connection values, see technical data. coupling and screw it onto the Connect the supply hose (recomm. spray lance. width 5-10 m, min. diameter 1/2”) to the Working with detergent device’s water connection and to the water supply (such as to the tap).
  • Page 18: Transport

    Transport Disconnecting the device Set the main switch to “0” position. Danger Remove the plug from the Risk of injury and damage! Observe the power outlet. machine’s weight for transport. Shut off the water supply. To move the device long distances, Operate the manual spray gun until pull it by the handle.
  • Page 19: Troubleshooting

    Troubleshooting Before each service Check the power cord for damage (risk Danger of electric shock), and have the Danger of injury caused by a device damaged power cord replaced starting up inadvertently and immediately by a service electric shock. technician/electrician. Before carrying out any work on the Make sure there is no damage to the device, disconnect it from the mains.
  • Page 20: Spare Parts

    The pump is not watertight Losing 3 drops of water per minute is acceptable, which may come out of the bottom of the device. In case of major leakage, contact customer service. In case of major leakage, have technical service inspect the device. The pump is thumping Check the watertightness of water and detergent tubes.
  • Page 21: Grounding And 3-Pin Plug

    Grounding and To disconnect the high-pressure washer, only pull by the plug and never pull the 3-pin plug power cord, to prevent damage. Remove the plug from the outlet before performing any maintenance or cleaning on the high-pressure washer. RISK OF Failing to follow these instructions could ELECTRIC SHOCK result in risk of death, fire or electric shock.
  • Page 22: Technical Data

    Technical data Model HD 6/15 C Mains connection Voltage Current type 1~60 1~50 1~60 1~50 Current Mains fuse (slow blow, expensive, C) IPX5 Protection class Maximum allowable network impedance 0.302+j0.189 Max. extension 30 m Water connection Input temperature (max.) ºC Supply speed (min.)
  • Page 23: Warranty

    Warranty The warranty conditions established by our distribution company are applicable in all countries. Device faults will be repaired free of charge within the warranty period, provided they are due to material or manufacturing defects. In a warranty case, please contact the dealer where you purchased the machine or your nearest authorized customer service center with proof of purchase.
  • Page 24 HECHO EN BRASIL POR / MADE IN BRAZIL BY KÄRCHER INDÚSTRIA E COMÉRCIO LTDA. VIA MIGUEL MELHADO CAMPOS, 600 VINHEDO - SP - BRASIL - CEP 13.288-003 / ZIP CODE 13.288-003 CENTRAL DE ATENDIMENTO: 08000-176111 www.karcher.com.br / www.karcher.com...

Table of Contents