TIF Series
Multi-Function Batching Paddle Wheel Flow Meter
Installation
Very Important
■
Lubricate O-rings with silicone (provided).
■
Using an alternating twisting motion, carefully lower the sensor
into the fitting.
|
Do Not Force
■
Ensure tab/notch are parallel to flow direction
Fig - 1
Hand tighten the sensor cap. DO NOT use tools.
Correct Sensor Position
01
Tab
Notch
Locate the flow meter positioning
tab and clamp saddle notch.
23-0069
|
See Fig 5
|
See Fig-2
Fig - 2
VERY IMPORTANT
Lubricate O-rings with silicone
02
Notch
Engage one thread of the sensor cap,
then turn the sensor until the alignment
tab is seated in the fitting notch.
Ensure tab is parallel to flow direction.
Retention Cap
TIB Series
TIB Series
TIB Series
TIB Series
Lubricate with
silicone inside of
insertion fitting
Fig - 3
Retention Cap
Flow
Process Pipe
Fig - 4
Top View
TIB Series
TIB Series
TIB Series
TIB Series
Fig - 5
03
Hand tighten
• Hand tighten
• DO NOT use tools
• Ensure meter is firmly in place
TIB Series
Locating Pin
Ensure
O-rings
are well
lubricated
Notch
1¼" G
Sensor Blade
Ensure
tab is parallel
TIB Series
to flow
direction
DO NOT use
display to
tighten
3