Intended use

The product is used together with the VAS 6606 isolator box to test cell modules in MEB
traction batteries as part of the diagnostics prescribed by the vehicle manufacturer.
The product is suitable for the following diagnostics:
Measuring the cell voltage
Reading out the temperature sensors
The product is not used to test that the circuit is de-energized.
Use only the plug connections on the vehicle that the manufacturer has specified in the
guided fault finding.
In this operating manual, vehicle manufacturers are exclusively defined as vehicle
manufacturers in the Volkswagen Group.
Any use beyond what is listed here is prohibited.

Requirements for the target group

Only qualified personnel may work with this product!
In this operating manual, qualified personnel is defined as personnel meeting all
requirements for working on high-voltage systems applicable in the country of operation, as
defined by:
Regulations applicable in the country of operation
Qualification according to DGUV 200-005 level 2 or higher, or equivalent
Specifications from the vehicle manufacturer and/or the operator.
At all times while using the product, staff must wear the personal protective equipment
prescribed by the vehicle manufacturer for work on high-voltage systems.

Duties of the operator

The operator is responsible for ensuring that all staff working with the adapter cable fulfills
the requirements for the target group.
Furthermore, the operator is responsible for ensuring the following:
The adapter cable is always in perfect working order.
The regular inspection intervals for the adapter cable are observed and recorded.
32.VW.2210.2720_BA_V01_EN