Advertisement

Quick Links

Operating manual
A d a p t e r c a b l e V A S 6 6 0 6 / 2 6
32.VW.2210.2720_BA_V01_EN
VAS 6606/26
1

Advertisement

Table of Contents
loading

Summary of Contents for Volkswagen VAS 6606/26

  • Page 1 Operating manual A d a p t e r c a b l e V A S 6 6 0 6 / 2 6 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 2: Legal Notice

    Symbols for warnings, prohibitions, mandatory actions and standards are taken from publicly accessible sources, such as the Internet. CAD product images and product photos are provided by the manufacturer. Images showing the product in use are provided with a reference to the source. 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 3: Table Of Contents

    PRODUCT DESCRIPTION Scope of delivery Design Symbols and connections Wiring diagram Technical data OPERATION Startup Detaching the plug connections Detaching the isolator box plug (66-pin) Detaching the battery module plug Cleaning Disposal Maintenance HELP Warranty Customer service 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 4: Introduction

    With extensive experience in software and hardware development, CAR-connect is your dependable partner at every production stage, from prototyping to series production. CAR-connect GmbH – Experience, Expertise and Innovation – MADE IN GERMANY 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 5: Safety

    This operating manual is only valid for the following product: Item number 22102720 Designation Adapter cable VAS 6606/26 Warning levels This chapter provides information about the warning levels used in this operating manual. DANGER Failure to observe the safety instructions WILL result in death or serious injury!
  • Page 6: Important Safety Instructions

    Defective and damaged products cannot guarantee protection against electrical voltage! • Do not let the product come into contact with chemicals! • Replace a defective or damaged product immediately! • Never attempt to repair or tamper with the product! 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 7: Intended Use

    Use only the plug connections on the vehicle that the manufacturer has specified in the guided fault finding. In this operating manual, vehicle manufacturers are exclusively defined as vehicle manufacturers in the Volkswagen Group. Any use beyond what is listed here is prohibited. Requirements for the target group...
  • Page 8: Product Description

    Immediately check the condition of the product and the completeness of the delivery. If anything is missing or defective, please contact the manufacturer immediately. (1) Adapter cable (2) USB stick with operating manual Design Product design: (1) Plug for battery module (2) Plug for isolator box 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 9: Symbols And Connections

    The CE marking certifies that the product complies with all applicable European regulations and has been subjected to the prescribed conformity assessment procedure. The test seal identifies the product as having been approved for use in workshops and production facilities belonging to the vehicle manufacturer. Wiring diagram 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 10: Technical Data

    Max. 2000 m No limitation. Humidity Max. 80 % up to 31° C, Max. 85 % decreasing linearly to 50 % at 40° C Condensation not permitted. Maximum permissible relative humidity: 60 % in environments with corrosive gas/air. 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 11: Operation

    • Use the product only for the applications intended by the vehicle manufacturer! CAUTION Risk of damage! Plug connections lock into place when attached. • Unlock the plug connections before you detach them! (See chapter “Detaching the plug connections”) 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 12: Startup

    3. Connect the plug for the isolator box to the appropriate slot on the VAS 6606 isolator box. 4. Push the lever up. This pulls the plug into the plug connection.  You can now perform measurements in accordance with the guided fault finding. 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 13: Detaching The Plug Connections

    Detaching the battery module plug The plug connection has an automatic locking mechanism. To release the plug connection: 1. Push in and hold the locking mechanism. 2. Pull the plug connection apart.  The plug connection is now detached. 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 14: Cleaning

    Observe the safety instructions! National and local requirements for regular testing must be observed! Test the product for proper function at intervals of no more than 24 months. Contact the manufacturer to have a professional function test performed. 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 15: Help

    Always include the serial number with any product queries. This number is found on the product. CAR-connect GmbH Am Egelingsberg 8 38542 Leiferde, Germany Phone: +49 (0) 5373 – 92197-0 Fax: +49 (0) 5373 – 92197-88 service@car-connect.cc www.car-connect.cc 32.VW.2210.2720_BA_V01_EN VAS 6606/26...
  • Page 16 Volkswagen Aktiengesellschaft K-GVO-LW Group After Sales – Group Service Literature and Systems Repair Shop Equipment PO box 011/4915 38442 Wolfsburg, Germany For internal use only Subject to technical changes Edition 03 / 2021 32.VW.2210.2720_BA_V01_EN VAS 6606/26...

Table of Contents