Operation; Position Of Operating Elements - Endress+Hauser Cerabar M PMC51 Operating Instructions Manual

Process pressure measurement
Hide thumbs Also See for Cerabar M PMC51:
Table of Contents

Advertisement

Operation

24
5
Operation
5.1

Position of operating elements

The operating keys and DIP switch are located on the electronic insert in the device.
Fig. 18:
Electronic insert
1
Operating keys for lower range value (zero) and upper range value (span)
2
Green LED to indicate successful operation
3
Slot for optional local display
4
DIP switch for switching damping on/off
5.1.1
Function of the DIP switch
"off"
Damping is switched off.
The output signal follows measured value
changes without any delay.
Display
Zero
Span
1
Switch position
"on"
Damping is switched on.
The output signal follows measured value
changes with the delay time Factory
setting: = 2 s or as per order specifications).
Cerabar M Analog
on
off
on
off
P01-Mxxxxxxx-19-xx-xx-xx-010
Endress+Hauser