Endress+Hauser
Loosen device 1 (here FQR56) and move it slowly by a = ±10 mm (±0.4 in) until a
signal maximum is reached (LED signal strength), fix device again.
Example:
Then loosen device 2 (here FDR56) and move it slowly by b = ±10 mm (±0.4 in) until
a signal maximum is reached, fix the device again.
Example:
Position change performed (here horizontal shift)
‣ Perform automatic adjustment again
5�1�3

Reflector operation

Direct comparison of FQR56 and FDR56 not possible�
‣ Deflect microwave beam via plane metal mirrors (reflectors).
5
Reflector operation
1
Reflector
α
Angle of entrance = angle of emission
• Arrange devices symmetrically to the reflector (entrance angle = exit angle).
• Range reduction per reflector: 10 %
5�1�4

Parallel operation

Mutual interference is to be avoided�
‣ Rotate every second microwave barrier by 90°.
α
6
Parallel operation
A
Distance between microwave barriers
D
Detection range
α
90°
1
1
A
D
Mounting
1
0000000165
α
0000000167